相关论文: Commissioning of the CMS zero degree calorimeter u…
The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling…
The combined zero degree calorimeter (ZDC) is a combination of sampling quartz/tungsten electromagnetic and hadronic calorimeters. Two identical combined calorimeters are located in the LHC tunnel at CERN at the straight section ~140 m on…
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters…
After nearly two decades of design, construction and commissioning, the CMS detector was operated with colliding LHC proton beams for the first time in November 2009. Collision data were recorded at centre-of-mass energies of 0.9 and 2.36…
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years…
Calibration of the forward CMS hadron calorimeters in situ by the LHC beam is proposed. Simulations show that bent crystal channeling technique is feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by…
The CMS collaboration used the past year to greatly improve the level of detector readiness for the first collisions data. The acquired operational experience over this year, large gains in understanding the detector and improved…
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of…
The first LHC pp collisions at centre-of-mass energies of 0.9 and 2.36 TeV were recorded by the CMS detector in December 2009. The trajectories of charged particles produced in the collisions were reconstructed using the all-silicon Tracker…
The CMS Zero Degree Calorimeters, ZDCs, will measure photons and neutrons emitted with |eta|> 8.6 from Pb+Pb, p+Pb and p+p collisions at sqrt(Snn)=5.5, 8.8 and 14 TeV respectively. The calorimeter consists of an electromagnetic part…
We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995…
The Compact Muon Solenoid (CMS) Experiment is a general purpose particle detector experiment located at the Large Hadron Collider (LHC) at CERN. In 2008, the LHC beam was commissioned and successfully steered through the CMS detector. First…
Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the…
We present first results from the ATLAS Zero Degree Calorimeters (ZDC) based on 7~TeV pp collision data recorded in 2010. The ZDC coverage of +/-~350 microradians about the forward direction makes possible the measurement of neutral…
The status of the CMS experiment is described. After a brief review of the detector design and a short overview of the first 5 years of assembly, the focus of this presentation will be the parallel activities of completing and commissioning…
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the…
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the current instantaneous luminosity by a factor of 5 to 7, providing the opportunity to study rare processes and measure precisely the standard model…
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate…
This paper describes the experience with the calibration, reconstruction and evaluation of the timing capabilities of the CMS HGCAL prototype in the beam tests in 2018. The calibration procedure includes multiple steps and corrections…
At the LHC, for the first time, laboratory energies are sufficiently large to reproduce the kind of reactions that occur when energetic cosmic rays strike the top of the atmosphere. The reaction products of interest for cosmic ray studies…