相关论文: All-reflective coupling of two optical cavities wi…
We demonstrate the optical coupling of two cavities without light transmission through a substrate. Compared to a conventional coupling component, that is a partially transmissive mirror, an all-reflective coupler avoids light absorption in…
We analyze an optical 3-port reflection grating by means of a scattering matrix formalism. Amplitude and phase relations between the 3 ports, i.e. the 3 orders of diffraction are derived. Such a grating can be used as an all-reflective,…
Reflection gratings enable light coupling to optical cavities without transmission through substrates. Gratings that have three ports and are mounted in second-order Littrow configuration even allow the coupling to high-finesse cavities…
We derive generic phase and amplitude coupling relations for beam splitters-combiners that couple a single port with three output ports or input ports, respectively. We apply the coupling relations to a reflection grating that serves as a…
Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively- coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption…
We report on the optical characterization of an ultra-high diffraction efficiency grating in 1st order Littrow configuration. The apparatus used was an optical cavity built from the grating under investigation and an additional high…
Coupling an emitter to a Fabry-P\'{e}rot optical cavity can provide a coherent and strong light-matter interface whose performance in a variety of applications depends critically on the emitter-photon coupling strength. Altering the…
We experimentally demonstrate the phase relations of 3-port gratings by investigating 3-port coupled Fabry-Perot cavities. Two different gratings which have the same 1st order diffraction efficiency but differ substantially in their 2nd…
All-reflective interferometry based on nano-structured diffraction gratings offers new possibilities for gravitational wave detection. We investigate an all-reflective Fabry-Perot interferometer concept in 2nd order Littrow mount. The…
We analyze the radiation pressure induced interaction of mirror motion and light fields in Michelson-type interferometers used for the detection of gravitational waves and for fundamental research in table-top quantum optomechanical…
Diffraction gratings have been proposed as core elements in future laser-interferometric gravitational-wave detectors. In this paper, we use a steady-state technique to derive coupling of lateral grating displacement to the output ports of…
Laser interferometers with high circulating power and suspended optics, such as the LIGO gravitational wave detectors, experience an optomechanical coupling effect known as a parametric instability: the runaway excitation of a mechanical…
We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in \emph{all} the light exiting to the detector with a large…
A new dielectric Fabry-Perot cavity was designed for a resonant enhancing optical absorption by a thin absorber layer embedded into the cavity. In this cavity, the front mirror is a subwavelength grating with $\sim 100$% retroreflection.…
We report on the first demonstration of a fully suspended 10m Fabry-Perot cavity incorporating a waveguide grating as the coupling mirror. The cavity was kept on resonance by reading out the length fluctuations via the Pound-Drever-Hall…
We develop a steady-state analytical and numerical model of the optical response of power-recycled Fabry-Perot Michelson laser gravitational-wave detectors to thermal focusing in optical substrates. We assume that the thermal distortions…
We analyze the electromagnetic fields in a Pound-Drever-Hall locked, marginally unstable, Fabry-Perot cavity as a function of small changes in the cavity length during resonance. More specifically, we compare the results of a detailed…
We present a cryogenic setup where an optical Fabry-Perot resonator is coupled to a single-mode optical fiber with coupling efficiency above 90% at mK temperatures without realignment during cooling down. The setup is prealigned at room…
We present, to the best of our knowledge, the first demonstration of an optical spring in a signal-recycled Michelson interferometer without arm cavities. The setup utilizes multiple laser fields to achieve stable and precisely controllable…
Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose…