中文
相关论文

相关论文: First underground results with NEWAGE-0.3a directi…

200 篇论文

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted…

NEWAGE is a direction-sensitive dark matter search experiment with a three-dimensional tracking detector based on a gaseous micro time projection chamber. A direction-sensitive dark matter search was carried out at Kamioka Observatory with…

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was…

NEWAGE(NEw generation WIMP search with an Advanced Gaseous tracking device Experiment) project is a direction-sensitive dark matter search experiment with a gaseous micro time-projection-chamber(micro-TPC). We report on the performance of…

NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the…

We developed a three-dimensional gaseous tracking device and performed a direction-sensitive dark matter search in a surface laboratory. By using 150 Torr carbon-tetrafluoride (CF_4 gas), we obtained a sky map drawn with the recoil…

The COUPP 4 kg bubble chamber employs 4.0 kg of CF$_3$I as a WIMP scattering target for use as a dark matter direct detection search. This thesis reports the first experimental results from operating this bubble chamber at the deep…

宇宙学与河外天体物理 · 物理学 2024-01-17 Drew Fustin

Tokyo group has performed first underground dark matter search experiment in 2001 through 2002 at Kamioka Observatory(2700m.w.e). The detector is eight LiF bolometers with total mass 168g aiming for the direct detection of WIMPs via…

天体物理学 · 物理学 2009-09-29 K. Miuchi , M. Minowa , A. Takeda , H. Sekiya , Y. Shimizu , Y. Inoue , W. Ootani , Y. Ootuka

The Dark Matter Time Projection Chamber (DMTPC) experiment uses CF_4 gas at low pressure (0.1 atm) to search for the directional signature of Galactic WIMP dark matter. We describe the DMTPC apparatus and summarize recent results from a…

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The…

A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a…

Light dark matter in the context of dark sector theories is an attractive candidate for the dark matter thought to make up the bulk of the mass of our universe. We explore here the possibility of using a low-pressure, negative-ion, time…

天体物理仪器与方法 · 物理学 2019-03-27 D. P. Snowden-Ifft , J. L. Harton , N. Ma , F. G. Schuckman

Direction-sensitive WIMP dark matter searches may help overcome the challenges faced by direct dark matter detection experiments. In particular, directional detectors should be able to clearly differentiate a dark matter signal from…

仪器与探测器 · 物理学 2014-02-04 Steven Ross

NEWAGE is a direction-sensitive dark-matter-search experiment that uses a micro-patterned gaseous detector, or {\mu}-PIC, as the readout. The main background sources are {\alpha}-rays from radioactive contaminants in the {\mu}-PIC. We have…

Gas-filled Time Projection Chambers (TPCs) with Gas Electron Multipliers (GEMs) and pixels appear suitable for direction-sensitive WIMP dark matter searches. We present the background and motivation for our work on this technology, past and…

天体物理仪器与方法 · 物理学 2015-05-30 S. E. Vahsen , H. Feng , M. Garcia-Sciveres , I. Jaegle , J. Kadyk , Y. Nguyen , M. Rosen , S. Ross , T. Thorpe , J. Yamaoka

The Dark Matter Time Projection Chamber (DMTPC) is a low pressure (75 Torr CF4) 10 liter detector capable of measuring the vector direction of nuclear recoils with the goal of directional dark matter detection. In this paper we present the…

The Dark Matter Time Projection Chamber collaboration recently reported a dark matter limit obtained with a 10 liter time projection chamber filled with CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the drift…

A new method of searching for dark matter in the form of weakly interacting massive particles (WIMP) has been developed with the direct detection of the low energy nuclear recoils observed in a massive target (ultimately many tons) of ultra…

The DEAP-3600 experiment is located 2 km underground at SNOLAB, in Sudbury, Ontario. It is a single-phase detector that searches for dark matter particle interactions within a 1000-kg fiducial mass target of liquid argon. A first generation…

‹ 上一页 1 2 3 10 下一页 ›