中文
相关论文

相关论文: Scintillator Non-Proportionality and Gamma Quenchi…

200 篇论文

We observe that the pattern of the quenching factors for scintillation light from various ions, recently studied in $CaWO_4$ in connection with dark matter detectors, can be understood as a saturation phenomenon in which the light output is…

仪器与探测器 · 物理学 2009-06-23 I. Bavykina , P. Christ , P. Huff , J. Ninkovic , F. Proebst , W. Seidel , L. Stodolsky

In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under {\alpha} and {\gamma} excitation. Concerning the scintillation decay…

The response of a CdWO4 crystal scintillator to protons, alpha particles, Li, C, O and Ti ions with energies in the range 1 - 10 MeV was measured. The non-proportionality of CdWO4 for low energy electrons (4 - 110 keV) was studied with the…

An increasing number of applications of scintillators at low temperatures, particularly in cryogenic experiments searching for rare events, has motivated the investigation of scintillation properties of materials over a wide temperature…

核实验 · 物理学 2010-03-16 V. B. Mikhailik , H. Kraus

The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even…

Future cryogenic experiments searching for rare events require reliable, efficient and robust techniques for the detection of photons at temperatures well below that to which low-temperature photomultipliers (PMT) were characterised.…

核实验 · 物理学 2010-05-24 H. Kraus , V. B. Mikhailik

High light collection efficiency is an important requirement in any application of scintillation detectors. The purpose of this study is to investigate the possibility for improving this parameter in cryogenic scintillation bolometers,…

仪器与探测器 · 物理学 2014-02-11 F. A. Danevich , R. V. Kobychev , V. V. Kobychev , H. Kraus , V. B. Mikhailik , V. M. Mokina

Eight PbWO4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 E13 p/cm2. The damage recovery in these crystals, stored in the dark at room…

仪器与探测器 · 物理学 2009-11-11 P. Lecomte , D. Luckey , F. Nessi-Tedaldi , F. Pauss

We present measurements of nonproportionality in the scintillation light yield of bismuth germanate (BGO) for gamma-rays with energies between 6 keV and 662 keV. The scintillation light was read out by avalanche photodiodes (APDs) with both…

仪器与探测器 · 物理学 2015-05-04 T. R. Gentile , M. J. Bales , H. Breuer , T. E. Chupp , K. J. Coakley , R. L. Cooper , J. S. Nico , B. O'Neill

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass…

仪器与探测器 · 物理学 2009-10-31 P. Meunier , M. Bravin , M. Bruckmayer , S. Giordano , M. Loidl , O. Meier , F. Proebst , W. Seidel , M. Sisti , L. Stodolsky , S. Uchaikin , L. Zerle

We report the performances of a 0.51 kg CdWO4 scintillating bolometer to be used for future Double Beta Decay Experiments. The simultaneous read-out of the heat and the scintillation light allows to discriminate between different…

核实验 · 物理学 2014-11-21 C. Arnaboldi , J. W. Beeman , O. Cremonesi , L. Gironi , M. Pavan , G. Pessina , S. Pirro , E. Previtali

Energy resolution, light yield, non-proportionality in the scintillation response, alpha/beta ratio, pulse shape for gamma rays and alpha particles were studied with CdWO4 crystal scintillators. Some indication for a difference in the…

The multi-TeV energy region of the cosmic-ray spectra has been recently explored by direct detection experiments that used calorimetric techniques to measure the energy of the cosmic particles. Interesting spectral features have been…

Prompted by intriguing events observed in certain particle-physics searches for rare events, we study light and acoustic emission simultaneously in some inorganic scintillators subject to mechanical stress. We observe mechanoluminescence in…

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding…

Semi-empirical method of calculation of quenching factors for scintillators is described. It is based on classical Birks formula with the total stopping powers for electrons and ions which are calculated with the ESTAR and SRIM codes,…

核实验 · 物理学 2010-03-19 V. I. Tretyak

A compact gamma-ray detector module was developed and characterized for spectroscopic applications across a wide energy range. The detector comprises a 4x4 array of silicon photomultipliers (SiPMs, Hamamatsu MPPC S13360-3050) coupled with…

仪器与探测器 · 物理学 2025-10-01 S. Nuruyev , G. Ahmadov , D. Berikov , M. Holik , F. Ahmadov , A. Sadigov , R. Akbarov , J. Naghiyev , I. Nuruyev , A. Mammadli

Application of CaMoO4 as a scintillation target in cryogenic rare event searches relies on the understanding of scintillation properties of the material at the temperatures at which these detectors operate. We devised and implemented a…

材料科学 · 物理学 2015-08-12 X. Zhang , J. Lin , V. B. Mikhailik , H. Kraus

We investigate the influence of oxygen annealing on the room temperature optical and scintillation properties of CaWO$_4$ single crystals that are being produced for direct Dark Matter search experiments. The applied annealing procedure…

In the context of the ClearMind project, we measured the scintillating properties, as induced from from gamma ray interactions, of today available PbWO4 crystal. We measured scintillation s yields and time constants by measuring the signal…

仪器与探测器 · 物理学 2021-09-01 M. Follin , V. Sharyy , J-P. Bard , M. Korzhik , D. Yvon
‹ 上一页 1 2 3 10 下一页 ›