相关论文: Interpretation of the Underground Muon Charge Rati…
MINOS is the first large magnetic detector deep underground and is the first to measure the muon charge ratio with high statistics in the region near 1 TeV.\cite{bib:adamson} An approximate formula for the muon charge ratio can be expressed…
The magnetized MINOS near detector can accurately determine the charge sign of atmospheric muons, this facilitates a measurement of the atmospheric muon charge ratio. To reduce the systematic error associated with geometric bias and…
The charge ratio, $R_\mu = N_{\mu^+}/N_{\mu^-}$, for cosmogenic multiple-muon events observed at an under- ground depth of 2070 mwe has been measured using the magnetized MINOS Far Detector. The multiple-muon events, recorded nearly…
The 5.4 kton MINOS far detector has been taking charge-separated cosmic ray muon data since the beginning of August, 2003 at a depth of 2070 meters-water-equivalent in the Soudan Underground Laboratory, Minnesota, USA. The data with both…
Observed since the 1950's, the seasonal effect on underground muons is a well studied phenomenon. The interaction height of incident cosmic rays changes as the temperature of the atmosphere changes, which affects the production height of…
The magnetized MINOS Near Detector, at a depth of 225 meters of water equivalent (mwe), is used to measure the atmospheric muon charge ratio. The ratio of observed positive to negative atmospheric muon rates, using 301 days of data, is…
The temperature of the upper atmosphere affects the height of primary cosmic ray interactions and the production of high-energy cosmic ray muons which can be detected deep underground. The MINOS far detector at Soudan MN, USA, has collected…
We present a new measurement of air shower muons made during atmospheric ascent of the High Energy Antimatter Telescope balloon experiment. The muon charge ratio mu+ / mu- is presented as a function of atmospheric depth in the momentum…
Theoretical calculations predict a small fractional difference in energy loss for $\mu^+$ and $\mu^-$ of the order of $0.15 %$ at high energies. This is predominantly due to a $z^3$ term in an extended ionization $dE/dX$ relation, in…
A sample of 1.53$\times$10$^{9}$ cosmic-ray-induced single muon events has been recorded at 225 meters-water-equivalent using the MINOS Near Detector. The underground muon rate is observed to be highly correlated with the effective…
An observation of seasonal variations in underground muon rate, $R_{\mu}$, has been performed at Soudan, MN, by the MINOS Far Detector. The four percent fluctuation seen over three years was highly correlated to the temperature variations…
The charge ratio ${k \equiv \mu^+/\mu^-}$ for atmospheric muons has been measured using Large Volume Detector (LVD) in the INFN Gran Sasso National Laboratory, Italy (minimal depth is 3000 m w.e.). To reach this depth muons should have the…
We present a new measurement of atmospheric muons made during an ascent of the High Energy Antimatter Telescope balloon experiment. The muon charge ratio mu+/mu- as a function of atmospheric depth in the momentum interval 0.3-0.9 GeV/c is…
By exploiting differences in muon lifetimes it is possible to distinguish $\nu_{\mu}$ from $\bar{\nu_{\mu}}$ charged current interactions in underground neutrino detectors. Such observations would be a useful tool in understanding the…
The muon charge ratio of the lateral muon density distributions in single EAS is studied by simulations, in context of recent proposals to measure this observable in coincidence with EAS observations. While effects of the hadronic…
A measurement is presented of the flux ratio of positive and negative muons from cosmic ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The excellent…
The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime during the 2008…
The Underground Muon Detector of the Pierre Auger Observatory features a calorimetric detection mode that estimates the number of muons based on signal charge measurements. This contribution provides an overview of the calibration…
We have performed the measurement of the cosmic ray muon charge ratio, as a function of the muon momentum, using data collected by the CMS experiment, exploiting the capabilities of the muon barrel drift tube (DT) chambers. The cosmic muon…
This paper describes a new measurement of the flux ratio of positive and negative muons from cosmic-ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The…