相关论文: Multi-wavelength Calibration Procedure for the Pie…
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a 375 nm light source at the telescope aperture. This end-to-end technique accounts for the combined effects of all detector components in a single…
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the…
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the ombined effects of all detector components in a single measurement. The calibrated 2.5…
A method of absolute calibration for large aperture optical systems is presented, using the example of the Pierre Auger Observatory fluorescence detectors. A 2.5 m diameter light source illuminated by an ultra--violet light emitting diode…
The absolute calibration of an air fluorescence detector (FD) is an important element in correctly determining the energy of detected cosmic rays. The absolute calibration relates the flux of photons of a given wavelength at the detector…
The stability of the fluorescence telescopes of the Pierre Auger Observatory is monitored with the optical relative calibration setup. Optical fibers distribute light pulses to three different diffuser groups within the optical system. The…
The aperture of the Fluorescence Detector (FD) of the Pierre Auger Observatory is evaluated from simulated events using different detector configurations: mono, stereo, 3-FD and 4-FD. The trigger efficiency has been modeled using shower…
The Pierre Auger Observatory is designed to study cosmic rays of the highest energies ($>10^{19}$ eV). The ground array of the Observatory will consist of 1600 water Cherenkov detectors deployed over 3000 km^2. The remoteness and large…
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers…
Air fluorescence detectors measure the energy of ultra-high energy cosmic rays by collecting fluorescence light emitted from nitrogen molecules along the extensive air shower cascade. To ensure a reliable energy determination, the light…
At the southern site of the Pierre Auger Observatory, which is close to completion, an exposure that significantly exceeds the largest forerunner experiments has already been accumulated. We report a measurement of the cosmic ray energy…
The Pierre Auger Observatory is a facility designed for the study of ultra-high energy cosmic rays. The Observatory combines two different types of detectors: a surface array of 1600 water Cherenkov stations placed on a 1.5 km triangular…
The air fluorescence detectors (FDs) of the Pierre Auger Observatory are vital for the determination of the air shower energy scale. To compensate for variations in atmospheric conditions that affect the energy measurement, the Observatory…
Major uncertainties in the fluorescence energy measurement come from the precision of various atmospheric transmission, air Cerenkov subtraction, light multiple-scattering and cloud corrections. The Auger program for atmospheric monitoring,…
The southern site of the Pierre Auger Observatory is under the construction near Malargue in Argentina and now more than 60% of the detectors are completed. The observatory has been collecting data for over 1 year and the cumulative…
The Pierre Auger Observatory is a hybrid detector for ultrahigh energy cosmic rays (UHECR) with energies above 10$^{18.5}$ eV. Currently the first part of the Observatory nears completion in the southern hemisphere in Argentina. One…
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10…
With the Auger Engineering Radio Array (AERA) located at the Pierre Auger Observatory, radio emission of extensive air showers is observed. To exploit the physics potential of AERA, electric-field amplitude measurements with the radio…
A novel and simple approach to optical wavelength measurement is presented in this paper. The working principle is demonstrated using a tunable waveguide micro ring resonator and single photodiode. The initial calibration is done with a set…
We present a detailed statistical treatment of the energy calibration of hybrid air-shower detectors, which combine a surface detector array and a fluorescence detector, to obtain an unbiased estimate of the calibration curve. The special…