相关论文: Synchrotron Radiation Interferometer Calibration C…
An interferometer system and an imaging system using visible synchrotron radiation (SR) have been installed in HLS II storage ring. Simulations of these two systems are given using Synchrotron Radiation Workshop(SRW) code. With these two…
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of…
A beam profile monitor utilizing visible synchrotron radiation (SR) from a bending magnet has been designed and installed in Cornell Electron-Positron Storage Ring (CESR). The monitor employs a double-slit interferometer to measure both the…
The ionization profile monitors (IPMs) are used to measure the beam size in synchrotrons. Both the Fermilab Recycler and Main Injector (MI) machines have IPMs. However, they were not well understood enough to provide confidence in their…
We describe operation of the CESR-TA vertical beam size monitor (xBSM) with $e^\pm$ beams with $E_{\rm b}$=4 GeV. The xBSM measures vertical beam size by imaging synchrotron radiation x-rays through an optical element onto a detector array…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…
The method for calibrating elevation measurements at EKB ISTP SB RAS radar obtained for the period 20/09/2019 - 18/11/2019 is presented. The calibration method is a modernization of the method for calibrating radar by meteor trails. The…
Spectroscopic investigations provide important insights into the composition of luminescence emissions relevant to trapped-charge dating of sediments. Accurate wavelength calibration and a correction for the wavelength-dependent detection…
Channel measurements in MIMO systems hinge on precise synchronization. While methods for time and frequency synchronization are well established, maintaining real-time phase coherence remains an open requirement for many MIMO systems. Phase…
Flux calibration of spectra in reverberation mapping (RM) is most often performed by assuming the flux constancy of some specified narrow emission lines, which stem from an extended region that is sometimes partially spatially resolved, in…
The techniques for optical calibration of Jefferson Lab's large-acceptance magnetic hadron spectrometer, BigBite, have been examined. The most consistent and stable results were obtained by using a method based on singular value…
This paper investigates a case study on measuring and controlling the first-order degree of spatial coherence under different coupling adjustments in the storage ring. The experimental findings are consistent with the predicted inverse…
We report on measurements and modeling studies performed from 2021 to 2024 on the 76 sextupole magnets in the Cornell Electron-positron Storage Ring CESR. Beam-based, magnet-specific calibrations ($K_2$ value versus excitation current) were…
This article presents a method that uses turn-by-turn beam position data and k-modulation data to measure the calibration factors of beam position monitors in high energy accelerators. In this method, new algorithms have been developed to…
New and upcoming radio interferometers will produce unprecedented amounts of data that demand extremely powerful computers for processing. This is a limiting factor due to the large computational power and energy costs involved. Such…
Precise evaluation of the isotope shift (IS) factors for seven low-lying potassium (K) states is achieved using relativistic coupled-cluster (RCC) theory. The energies of these states are assessed and compared with experimental data to…
We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose the frequency deviations of the stabilization are measured precisely by…
The two output signals of quadrature phase interferometers allow to benefit both from the high sensitivity of interferometry (working inside a fringe) and from an extended input range (counting fringes). Their calibration to reach a linear…
Shanghai Synchrotron Radiation Facility (SSRF) is a 3.5 GeV storage ring with a bunch rate of 499.654 MHz, harmonic number of 720, and circumference of 432 meters. SSRF injection works at 3.5 GeV, where the multi-bunch instabilities limit…