仪器与探测器
A Prototype of the Iron Calorimeter for the India-based Neutrino Observatory is currently running in Madurai, India. This consists of twenty large area single gap Resistive Plate Chambers (RPCs) of size, $\sim$ 185\,cm $\times$ 175\,cm…
A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…
Scintillator detector response modelling has become an essential tool in various research fields such as particle and nuclear physics, astronomy or geophysics. Yet, due to the system complexity and the requirement for accurate electron…
Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the…
A novel methodology, named the diffusion profile method, is proposed in this research to measure the electric field of a low gain avalanche detector (LGAD).The proposed methodology utilizes the maximum of the time derivative of the edge…
Josephson junctions and the quantum phase-slip (QPS) junctions are two quantum circuit elements introduced by superconducting electronics to create various hybrid circuits. Josephson junctions bring the developments of superconducting…
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $\pi$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent…
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an…
Project 8 is a next generation experiment aiming to directly measure the neutrino mass using the tritium endpoint method with a targeted sensitivity of 40 meV. Having established a new measuring technique, Cyclotron Radiation Emission…
The multi-nucleon transfer reaction between 136Xe beam and 198Pt target at the beam energy 7 MeV/u was studied using the large acceptance spectrometer VAMOS++ coupled with the newly installed second arm time-of-flight and delayed…
HVE-400 ion implanter is special ion implantation equipment for semiconductor materials boron and phosphorus doping. The ion source and extraction deflection system are at high voltage platform, while the corresponding control system is at…
The antiProton Unstable Matter Annihilation experiment (PUMA) at CERN aims at investigating the nucleon composition in the matter density tail of radioactive as well as stable isotopes by use of low-energy antiproton-nucleon annihilation…
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms…
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in…
Endoscopic optical coherence tomography (OCT) is a valuable tool for providing diagnostic images of internal organs and guiding interventions in real time. Miniaturized OCT endoscopes are essential for imaging small and convoluted luminal…
Noise efficiency factor (NEF) and power efficiency factor (PEF) are widely used as the figure of merit to quantify the performance of biopotential recording front-ends. NEF and PEF are discussed from the noise analysis to the trend survey.…
Dark noise is a dominant background in photomultiplier tubes (PMTs), which are commonly used in liquid-filled particle detectors for single-photon detection to see the results of particle interactions. A major contribution to dark noise is…
Photomultiplier tube (PMT) and Silicon Photo Multiplier (SiPM) are often used for detecting small number of photons or very weak radiations. A light guide usually connects these photodetectors to the test space. In this article, we…
Kinetic Inductance Detectors (KIDs) are superconducting energy-resolving detectors, sensitive to single photons from the near-infrared to ultraviolet. We study a hybrid KID design consisting of a beta phase tantalum ($\beta$-Ta) inductor…
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$\nu$NS) for the…