Wireless Gas Leak Detection and Localization
摘要
Thousands of industrial gas leaks occur every year, with many leading to injuries, deaths, equipment damage, and a disastrous environmental effect. There have been many attempts at solving this problem, but with limited success. This paper proposes a wireless gas leak detection and localization solution. With a monitoring network of 20 wireless devices covering 200m^2, 60 propane releases are performed. The detection and localization algorithms proposed here are applied to the collected concentration data, and the methodology is evaluated. A detection rate of 91% is achieved, with seven false alarms recorded over three days, and an average detection delay of 108 seconds. The localization results show an accuracy of 5 meters. Recommendations for future explosive gas sensor design are then presented.
引用
@article{arxiv.2607.04524,
title = {Wireless Gas Leak Detection and Localization},
author = {Fabien Chraim and Yusuf Bugra Erol and Kris Pister},
journal= {arXiv preprint arXiv:2607.04524},
year = {2026}
}
备注
12 pages, 18 figures