Related papers: Characterising a Si(Li) detector element for the S…
Unique spectroscopic possibilities open up if a laser beam interacts with relativistic lithium-like ions stored in the heavy ion ring accelerator SIS300 at the future Facility for Antiproton and Ion Research FAIR in Darmstadt, Germany. At a…
We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…
We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…
The response of Low Gain Avalanche Diodes (LGADs), a type of thin silicon detector with internal gain, to X-rays of energies between 6-16~keV was characterized at the Stanford Synchrotron Radiation Lightsource (SSRL). The utilized beamline…
We report the preliminary R values for all the 85 energy points scanned in the energy region of 2-5 GeV with the upgraded Beijing Spectrometer (BESII) at Beijing Electron Positron Collider (BEPC). Preliminary results from the J/psi data…
Highly precise measurements of the $^{99}$Tc beta spectrum were performed in two laboratories using metallic magnetic calorimeters. Independent sample preparations, evaluation methods and analyses yield consistent results and the spectrum…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
This article describes the crystal selection and quality control utilized to develop and calibrate a high resolution array of CsI(TI) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the…
We are developing a Compton telescope based on high resolution Si and CdTe imaging devices in order to obtain a high sensitivity astrophysical observation in sub-MeV gamma-ray region. In this paper, recent results from the prototype Si/CdTe…
The silicon photo-multipliers (SiPMs) are commonly used in the construction of radiation detectors such as those used in high energy experiments and its applications, where an excellent time resolution is required for triggering. In most of…
We performed an analysis of coherence properties of the 4-th generation high-energy storage rings with emittance values of 10 pmrad. It is presently expected that a storage ring with these low emittance values will reach diffraction limit…
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed.…
We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT)…
An unparalleled resolution is reported with an inelastic x-ray scattering instrument at the Cu K-edge. Based on a segmented concave analyzer, featuring single crystal quartz (SiO_{2}) pixels, the spectrometer delivers a resolution near 25…
We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII detector. The control samples of the initial-state-radiation (ISR) process of $e^+e^-\rightarrow \gamma \mu^+\mu^-$ at…
Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal…
The detector for imaging of explosions (DIMEX) is in operation at the synchrotron radiation (SR) beam-line at VEPP-3 electron ring at Budker INP since 2002. DIMEX is based on one-coordinate gas ionization chamber filled with Xe-CO2(3:1)…
We describe the design, construction and performance of the PIBETA detector built for the precise measurement of the branching ratio of pion beta decay, pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the detector is a…
The performance of germanium detectors for high-energy $\gamma$-rays was evaluated using a 992-keV resonance in the $^{27}$Al(p, $\gamma$)$^{27}$Si reaction. The measurement was conducted at the RIKEN tandem accelerator. The energy of the…
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated…