Related papers: Characterising a Si(Li) detector element for the S…
In this paper we compare suitability of three different semi-insulating bulk silicon carbide (SiC) materials for fabrication of radiation detectors. We prepared planar sensors with various metal contact combination and characterized…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
An improved method of energy calibration of position-sensitive silicon detector is presented. Instead of the parabolic function used in traditional method, a new function describing the relation of position and energy is introduced and…
Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers namely the thicknesses of dead layer, beryllium window and crystal…
Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…
The quadrant silicon detector, a kind of passivated implanted planar silicon detector with quadrant structure on the junction side, gained its wide application in charged particle detection. In this paper, the manufacturing procedure,…
Dependence of the secondary electron yield (SEY) from the primary beam incident energy and the coverage has been measured for neon, argon, krypton and xenon condensed on a target at 4.2K. The beam energy ranged between 100 eV and 3 keV, the…
Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$\nu$NS). Here, we present results from a novel 100 g…
Energy dispersive X-ray fluorescence (EDXRF) is a widely used non-destructive technique for micro and trace multi-element analysis of materials. Conventional trials show that using laboratory assisted EDXRF measurements, one can obtain…
The precision measurement of the $\beta-$spectrum shape for $^{210}$Bi (historically RaE) have been performed with a spectrometer based on semiconductor Si(Li) detector. This first forbidden non-unique transition has the transition…
Investigated in this work are sensitivities to non-standard neutrino interactions (NSI) of a prototype detector placed about 20 meters away from the Spallation Neutron Source at the Oak Ridge National Laboratory in two years of data taking.…
We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons impinging on…
A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…
We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles…
3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders…
The Soft X-ray Imager (SXI) is an imaging spectrometer using charge-coupled devices (CCDs) aboard the Hitomi X-ray observatory. The SXI sensor has four CCDs with an imaging area size of $31~{\rm mm} \times 31~{\rm mm}$ arranged in a $2…
The spectrum of the 0.1-7.0 keV cosmic X-ray background (CXB) at galactic latitudes >|25| degrees has been measured using the BeppoSAX Low-Energy Spectrometer Concentrator (LECS). Above 1 keV the spectrum is consistent with a power-law of…
The time resolution of the second monolithic silicon pixel prototype produced for the MONOLITH H2020 ERC Advanced project was studied using a femtosecond laser. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch, readout…
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX…