Related papers: Simulation of a fine grained GEM used in the PixiE…
The Gas Electron Multiplier (GEM) manufacturing technique has recently evolved to allow the production of large area GEMs. A novel approach based on single mask photolithography eliminates the mask alignment issue, which limits the…
The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON…
The new generation of X-ray polarisation detectors, gas pixel detectors, which will be employed by the future space missions IXPE and eXTP, allows for spatially resolved X-ray polarisation studies. This will be of particular interest for…
X-ray polarimetry has great scientific potential and new experiments, such as X-Calibur, PoGOLite, XIPE, and GEMS, will not only be orders of magnitude more sensitive than previous missions, but also provide the capability to measure…
Discrete particle simulations are used to model segregation in granular mixtures of three different particle species in a horizontal rotating drum. Axial band formation is observed, with medium-size particles tending to be located between…
Linear polarization of high-energy gamma-rays (10 MeV-100 GeV) can be detected by measuring the azimuthal angle of electron-positron pairs and observing the modulation of the azimuthal distribution. To demonstrate the gamma-ray polarization…
Spectroscopic measurements are presented using the PID350 pixelated gamma radiation detectors. A high-speed data acquisition system has been developed in order to reduce the data loss during the data reading in case of a high flux of…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
Measurements and numerical simulations on the charge transfer in Gas Electron Multiplier (GEM) foils are presented and their implications for the usage of GEM foils in Time Projection Chambers are discussed. A small test chamber has been…
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this…
A large-area and light-weight Gas Electron Multiplier (GEM) detector was built at the University of Virginia as a prototype for the detector R$\&$D program of the future Electron Ion Collider. The prototype has a trapezoidal geometry…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
Advances in fabrication techniques and high-performance electronics have facilitated the development of fine-pitch Gas Electron Multipliers (GEMs). Earlier experimental and simulation findings suggest that these reduced-pitch GEMs can…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between electrodes are created. The chambers containing MGEMs (WGEMs) with pin-anodes are proposed as detectors for…
A gaseous beam monitor utilizing gas electron multiplier (GEM) and pixel sensors is being developed for the Cooling Storage Ring (CSR) External-target Experiment (CEE) at Heavy Ion Research Facility in Lanzhou (HIRFL). The beam monitor is…
Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One…
Refraction-enhanced x-ray radiography (REXR) is used to infer shock-wave positions of more than one shock wave, launched by a multiple-picket pulse in a planar plastic foil. This includes locating shock waves before the shocks merge, during…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…