Related papers: Simulation of a fine grained GEM used in the PixiE…
Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design…
The Gas Electron Multiplier (GEM) detectors has been utilized for various applications due to their excellent spatial resolution, high rate capabilities and flexibility in design. The GEM detectors stand as a promising device to be used in…
Transition-edge sensors (TESs) are capable of highly accurate single particle energy measurement. TESs have been used for a wide range of photon detection applications, particularly in astronomy, but very little consideration has been given…
We report on the R&D effort in the design and construction of a large size Gas Electron Multiplier (GEM) for the Proton Polarimeter Back Tracker (BT) of the Super Bigbite Spectrometer (SBS) in Hall A at Thomas Jefferson National Laboratory…
A fast, hydrodynamic numerical model has been developed on the COMSOL Multi-physics platform to simulate the evolution and dynamics of charged particles in gaseous ionization detectors based on the Gaseous Electron Multipliers (GEM).…
Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work,…
The design and the simulated performances of a compact detector dedicated to the measurement of GRB photon polarization is presented. Such a detector would permit to answer the question ``are most of the GRB strongly polarized?'' in a…
The polarisation of x-ray photons can be determined by measuring the direction of emission of a K-shell photoelectron. Effective exploitation of this effect below 10 keV would allow development of a highly sensitive x-ray polarimeter…
The development of the first X-ray polarimeter, based on the photoelectric effect 20 years ago and implemented thanks to advances in gas amplification structures and readout techniques, had a significant impact in opening a new window for…
Earlier we have developed and successfully tested a RICH detector prototype consisting in a CsI coated triple GEM operated in gas flushed mode In the given work, a modified version of this detector for a completely different application -…
Gaseous detectors are used in both low energy and high energy physics experiments. The present day gaseous detectors, i.e., the Micro-Pattern gaseous detectors (MPGD) are more efficient and fast. Gas Electron multiplier (GEM) is quite well…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
Study of the uniformity of gain, energy resolution and count rate over active area of a triple GEM detector has been performed using a strong Fe55 X-ray source with premixed gas of Argon and CO2 in 70/30 ratio and conventional NIM…
Non destructive quality control of microstructures at the manufacturing stage is an important issue in the foreseen use of huge numbers of such gaseous detectors in the future high luminosity colliders. In this work we report on the use of…
Transmission electron microscopy specimens typically exhibit local distortion at thin foil edges, which can influence the absorption of X-rays for quantitative energy dispersive X-ray spectroscopy (EDS). Here, we report a numerical,…
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the gravitational-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background…
Gas electron multipliers (GEMs) with wire (WGEMs) or metal electrodes (MGEMs), which don't use any plastic insulators between the electrodes are created. The absence of plastic insulation between the electrodes of WGEMs excludes unwanted…
We report on Monte Carlo studies of the hard X-ray polarimeter X-Calibur. The polarimeter will be used in the focal plane of a grazing incidence hard X-ray telescope. It combines a low-Z Compton scatterer with a high-Z Cadmium Zinc…
The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions…
Two GEM telescopes, each consisting of three 10x10 cm$^2$ triple-GEM chambers were built, tested and operated by the Hampton University group. The GEMs are read out with APV25 frontend chips and FPGA based digitizing electronics developed…