English
Related papers

Related papers: Two Models for Bolometer and Microcalorimeter Dete…

200 papers

We present two variants of a magnetic microcalorimeter with paramagnetic temperature sensors and integrated dc-SQUID readout for high-resolution X-ray emission spectroscopy. Each variant employs two overhanging gold absorbers with a…

Instrumentation and Detectors · Physics 2024-01-24 Matthäus Krantz , Francesco Toschi , Benedikt Maier , Greta Heine , Christian Enss , Sebastian Kempf

The current and future cosmic microwave background (CMB) experiments fielding kilo-pixel arrays of transition-edge sensor (TES) bolometers require accurate and robust gain calibration methods. We simplify and refactor the standard TES model…

Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype…

Thermal convection based micro-electromechanical accelerometer is a relatively new kind of acceleration sensor that does not require a solid proof mass, yielding unique benefits like high shock survival rating, low production cost, and…

Applied Physics · Physics 2018-01-24 Rahul Mukherjee , Joydeep Basu , Pradip Mandal , Prasanta Kumar Guha

The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters…

Instrumentation and Detectors · Physics 2015-03-19 A. J. Anderson , S. W. Leman , T. Doughty , E. Figueroa-Feliciano , K. A. McCarthy , M. Pyle , B. A. Young

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters…

Instrumentation and Detectors · Physics 2022-08-01 CUORE Collaboration , D. Q. Adams , C. Alduino , K. Alfonso , F. T. Avignone , O. Azzolini , G. Bari , F. Bellini , G. Benato , M. Beretta , M. Biassoni , A. Branca , C. Brofferio , C. Bucci , J. Camilleri , A. Caminata , A. Campani , L. Canonica , X. G. Cao , S. Capelli , C. Capelli , L. Cappelli , L. Cardani , P. Carniti , N. Casali , E. Celi , D. Chiesa , M. Clemenza , S. Copello , O. Cremonesi , R. J. Creswick , A. D'Addabbo , I. Dafinei , F. Del Corso , S. Dell'Oro , S. Di Domizio , S. Di Lorenzo , V. Dompè , D. Q. Fang , G. Fantini , M. Faverzani , E. Ferri , F. Ferroni , E. Fiorini , M. A. Franceschi , S. J. Freedman , S. H. Fu , B. K. Fujikawa , S. Ghislandi , A. Giachero , A. Gianvecchio , L. Gironi , A. Giuliani , P. Gorla , C. Gotti , T. D. Gutierrez , K. Han , E. V. Hansen , K. M. Heeger , R. G. Huang , H. Z. Huang , J. Johnston , G. Keppel , Yu. G. Kolomensky , R. Kowalski , M. Li , R. Liu , L. Ma , Y. G. Ma , L. Marini , R. H. Maruyama , D. Mayer , Y. Mei , S. Morganti , T. Napolitano , M. Nastasi , J. Nikkel , C. Nones , E. B. Norman , A. Nucciotti , I. Nutini , T. O'Donnell , M. Olmi , J. L. Ouellet , S. Pagan , C. E. Pagliarone , L. Pagnanini , M. Pallavicini , L. Pattavina , M. Pavan , G. Pessina , V. Pettinacci , C. Pira , S. Pirro , S. Pozzi , E. Previtali , A. Puiu , S. Quitadamo , A. Ressa , C. Rosenfeld , S. Sangiorgio , B. Schmidt , N. D. Scielzo , V. Sharma , V. Singh , M. Sisti , D. Speller , P. T. Surukuchi , L. Taffarello , F. Terranova , C. Tomei , K. J. Vetter , M. Vignati , S. L. Wagaarachchi , B. S. Wang , B. Welliver , J. Wilson , K. Wilson , L. A. Winslow , S. Zimmermann , S. Zucchelli

Pulse-tube based dilution refrigerators are massively employed in low temperature physics. They allow to reduce the running costs and to be operated with unprecedented easiness. However, the main drawback of this technology is the…

Instrumentation and Detectors · Physics 2018-09-05 R. Maisonobe , J. Billard , M. De Jesus , A. Juillard , D. Misiak , E. Olivieri , S. Sayah , L. Vagneron

Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…

Instrumentation and Detectors · Physics 2023-10-26 Constantin Schuster , Sebastian Kempf

Next generation cosmic microwave background (CMB) polarimetry experiments aim to deploy order 500,000 detectors, requiring repeatable and reliable fabrication process with stable and uniform transition edge sensor (TES) bolometer…

Instrumentation and Detectors · Physics 2024-10-10 K. M. Rotermund , X. Li , R. Carney , D. Yohannes , R. Cantor , J. Vivalda , A. Chambal-Jacobs , A. Suzuki

We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky…

The CALICE collaboration is developing an engineering prototype of an analog hadron calorimeter for a future linear collider detector. The prototype has to prove the feasibility of building a realistic detector with fully integrated…

Instrumentation and Detectors · Physics 2019-08-13 Oskar Hartbrich , Mark Terwort

Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer…

Instrumentation and Detectors · Physics 2019-09-04 Daikang Yan , Lisa M. Gades , Tejas Guruswamy , Antonino Miceli , Umeshkumar M. Patel , Orlando Quaranta

It has been recently demonstrated that superconducting transition edge sensors (TESs) behave as weak-links due to longitudinally induced superconductivity from the leads with higher Tc. In this work we study the implication of this…

We propose to operate a superconducting transition edge sensor (TES) using a different type of biasing, in which the resistance of the TES is kept constant by means of feedback on the bias voltage and is independent of the incoming signal…

Instrumentation and Detectors · Physics 2015-06-12 Jan van der Kuur , Mikko Kiviranta

Thermal Kinetic Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of…

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics, science goals require very high resolution…

Instrumentation and Detectors · Physics 2021-02-19 E. Taralli , C. Pobes , P. Khosropanah , L. Fabrega , A. Camon , L. Gottardi , K. Nagayoshi , M. Ridder , M. Bruijn , J. R. Gao

The superconducting Transition-Edge Sensor (TES) is a critical technology for next-generation X-ray spectrometers, known for its exceptional energy resolution. In the last decade, TESs based on AlMn alloy films have been extensively used in…

Instrumentation and Methods for Astrophysics · Physics 2026-02-13 Liangpeng Xie , Yifei Zhang , Zhengwei Li , Zhouhui Liu , Shibo Shu , Junjie Zhou , Xufang Li , Haoyu Li , He Gao , Yudong Gu , Xuefeng Lu , Yong Zhao , Congzhan Liu

Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted…

Data Analysis, Statistics and Probability · Physics 2011-10-10 G. Piperno , S. Pirro , M. Vignati

Infrared (IR) radiation detectors are used in numerous applications from thermal imaging to spectroscopic gas sensing. Obtaining high speed and sensitivity, low-power operation and cost-effectiveness with a single technology remains to be a…

Transition-edge sensor (TES) is a highly sensitive device that is capable of detecting extremely low levels of energy. It is characterised by low noise performance and high energy resolution. A mature method for reading out TES signal is…

Instrumentation and Detectors · Physics 2025-02-11 N. Li , X. Ren , H. Gao , Z. Zhang , Y. Zhang , C. Liu , H. Li , Z. Li