Related papers: Two Models for Bolometer and Microcalorimeter Dete…
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a…
In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type…
We theoretically investigate the temperature-to-phase conversion (TPC) process occurring in dc superconducting quantum interferometers based on superconductor--normal metal--superconductor (SNS) mesoscopic Josephson junctions. In…
This review discusses detector physics and Monte Carlo techniques for cryogenic, radiation detectors that utilize combined phonon and ionization readout. A general review of cryogenic phonon and charge transport is provided along with…
The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020)…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
We propose a new type of a transition edge sensor based on an Al/AlOx/Ti/AlOx/Al superconductor - insulator - superconductor - insulator - superconductor (SIS'IS) structure. It exhibits sharp dependence of zero bias resistance on…
Cold electron bolometers have shown their suitability for use in modern fundamental physical experiments. Fabrication and measurements of the samples with cold-electron bolometers integrated into coplanar antennas are performed in this…
We describe the design and performance the calorimeter systems used in the ECCE detector design to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The…
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…
Experimental searches for axions or dark photons that couple to the standard model photon require photosensors with low noise, broadband sensitivity, and near zero backgrounds. Here, we introduce an experimental architecture, in which a…
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…
In high-sensitivity bolometers and calorimeters, the photon absorption often occurs at a finite distance from the temperature sensor to accommodate antennas or avoid the degradation of superconducting circuitry exposed to radiation. As a…
In this letter, we present the performance of a $100~\mu\mathrm{m}\times 400~\mu\mathrm{m} \times 40~\mathrm{nm}$ tungsten (W) Transition-Edge Sensor (TES) with a critical temperature of 40 mK. This device has a measured noise equivalent…
Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon…
We introduce a microwave bolometer aimed at high-quantum-efficiency detection of wave packet energy within the framework of circuit quantum electrodynamics, the ultimate goal being single microwave photon detection. We measure the…
The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…
An electrothermal model of Kinetic Inductance Detectors (KIDs) is described. The non-equilibrium state of the resonator's quasiparticle system is characterized by an effective temperature, which because of readout-power heating is higher…
We report initial measurements on our firstMoAu Transition Edge Sensors (TESs). The TESs formed from a bilayer of 40 nm of Mo and 106 nm of Au showed transition temperatures of about 320 mK, higher than identical TESs with a MoCu bilayer…
The performance of the electromagnetic calorimeter of the ALICE experiment during operation in 2010-2018 at the Large Hadron Collider is presented. After a short introduction into the design, readout, and trigger capabilities of the…