English
Related papers

Related papers: An automated and versatile ultra-low temperature S…

200 papers

The determination of their critical current density in the whole range of the temperature below Tc is of first importance to understand the physical processes occurring in superconducting films. We describe here a technique suitable for…

Superconductivity · Physics 2012-07-25 Conor McLoughlin , Pierre Bernstein , Yohann Thimont , J. Siejka

We describe the operation of a free-space confocal optical microscope operated in a dilution refrigerator. The microscope is installed on a cold insertable probe to enable fast sample exchange while the refrigerator is held at low…

Quantum Physics · Physics 2021-03-12 B. J. Lawrie , M. Feldman , C. E. Marvinney , Y. Y. Pai

We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses…

Instrumentation and Detectors · Physics 2020-03-24 Andreas Reifenberger , Andreas Reiser , Sebastian Kempf , Andreas Fleischmann , Christian Enss

We report on compact, gaseous 3He NMR probes for precision magnetometry of magnetic fields B > 0.1 T in the temperature range from ambient temperatures down to 4 Kelvin. The gas is polarized at thermal equilibrium under pressures up to 100…

Atomic Physics · Physics 2025-05-26 P. Blümler , M. Fertl , H. -J. Grafe , R. Graf , W. Heil

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz,…

In the framework of the diagrammatic method with self-consistent field, the maximum on the temperature dependence of the susceptibility of a weakly doped narrow-band Hubbard magnet below the Curie temperature $T_{\rm C}$ is predicted. By…

Strongly Correlated Electrons · Physics 2010-06-07 E. E. Zubov

We have described here the design and operation of an automated ac susceptibility set up using a closed cycle helium refrigerator. This set up is useful for measuring linear and nonlinear magnetic susceptibilities of various magnetic…

Instrumentation and Detectors · Physics 2011-09-22 S. Kundu , T. K. Nath

We present a 3He / 4He dilution refrigerator designed for cooling astronomical mm-wave telescope receivers to around 100 mK. Used in combination with a Gifford-McMahon closed-cycle refrigerator, 4He and 3He sorption-pumped refrigerators,…

Instrumentation and Methods for Astrophysics · Physics 2013-03-21 Simon J. Melhuish , Lorenzo Martinis , Lucio Piccirillo

We have successfully developed and tested a compact shielded superconducting (SSC) magnet with a FeCoV magnetic shield. This was developed for the PrNi$_5$ based nuclear demagnetization refrigerator which can keep temperatures below 1 mK…

Instrumentation and Detectors · Physics 2022-08-22 Shohei Takimoto , Ryo Toda , Satoshi Murakawa , Hiroshi Fukuyama

Scanning tunneling microscope (STM) is a powerful tool for studying the structural and electronic properties of materials at the atomic scale. The combination of low temperature and high magnetic field for STM and related spectroscopy…

Materials Science · Physics 2018-11-13 Syu-You Guan , Hsien-Shun Liao , Bo-Jing Juang , Shu-Cheng Chin , Tien-Ming Chuang , Chia-Seng Chang

Ultralow dissipation plays an important role in sensing applications and exploring macroscopic quantum phenomena using micro-and nano-mechanical systems. We report a diamagnetic-levitated micro-mechanical oscillator operating at a low…

We calculate the flux threading the pick-up coil of a square SQUID magnetometer in the presence of a current dipole source. The result reproduces that of a circle coil magnetometer calculated by Wikswo with only small differences. However…

Superconductivity · Physics 2009-11-13 S Rombetto , A Vettoliere , C Granata , M Russo , C Nappi

An excellent molecule-based cryogenic magnetic refrigerant, gadolinium acetate tetrahydrate, is here used to decorate selected portions of silicon substrate. By quantitative magnetic force microscopy for variable applied magnetic field near…

A simple and low cost apparatus has been designed and built to measure the electrical resistivity, ($\rho$), of metal and semiconductors in 300-620 K temperature range. The present design is suitable to do measurement on rectangular bar…

General Physics · Physics 2017-04-14 Saurabh Singh , Sudhir K. Pandey

A sensor for thermal and thermodynamic measurements of small magnetic systems have been designed and built. It is based on a 5μm-thick suspended polymer membrane, which has a very low heat capacity (≈ 10-6 J/K at nitrogen…

Mesoscale and Nanoscale Physics · Physics 2016-08-16 Olivier Bourgeois , Cristina Macovei , Emmanuel André , Jean-Luc Garden , Jacques Chaussy , Dominique Givord

Scanning nanoscale superconducting quantum interference devices (nanoSQUIDs) are of growing interest for highly sensitive quantitative imaging of magnetic, spintronic, and transport properties of low-dimensional systems. Utilizing…

Mesoscale and Nanoscale Physics · Physics 2020-01-13 Y. Anahory , H. R. Naren , E. O. Lachman , S. Buhbut Sinai , A. Uri , L. Embon , E. Yaakobi , Y. Myasoedov , M. E. Huber , R. Klajn , E. Zeldov

In this article a simple and easy to install low magnetic field extension of the SQUID magnetometer Quantum Design MPMS-7 is described. This has been accomplished by complementing the MPMS-7 magnet control system with a laboratory current…

Superconductivity · Physics 2013-12-02 M. Presnitz , M. Herzinger , E. -W. Scheidt , W. Scherer , M. Baenitz , M. Marz

We describe a new 17 T cryomagnet for neutron, x-ray or optical experiments with rapid in-situ sample change. Sample temperatures are controllable from < 2 K to 300 K in vacuum. Alternatively a room temperature bore insert can be used for…

We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…

Scanning superconducting quantum interference device (SQUID) microscopy is a magnetic imaging technique combining high-field sensitivity with nanometer-scale spatial resolution. State-of-the-art SQUID-on-tip probes are now playing an…

Mesoscale and Nanoscale Physics · Physics 2022-03-03 M. Wyss , K. Bagani , D. Jetter , E. Marchiori , A. Vervelaki , B. Gross , J. Ridderbos , S. Gliga , C. Schönenberger , M. Poggio
‹ Prev 1 3 4 5 6 7 10 Next ›