English
Related papers

Related papers: An automated and versatile ultra-low temperature S…

200 papers

An ongoing process of miniaturization of spintronics and magnetic-films-based devices, as well as a growing necessity for basic material research place stringent requirements for sensitive and accurate magnetometric measurements of minute…

Materials Science · Physics 2019-07-08 Katarzyna Gas , Maciej Sawicki

Pulsed readout of Direct Current (DC) SUperconducting Quantum Interference Device (SQUID) is crucial for experiments which need to be performed at millikelvin temperatures, such as the readout of superconducting and electron spin based…

Quantum Physics · Physics 2022-04-20 Josiah Cochran , C. S. Guzman , Eric Stiers , Irinel Chiorescu

Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…

Instrumentation and Detectors · Physics 2026-01-29 Nan Li , Mengjie Song , Sixiao Hu , Wentao Wu , Songqing Liu , Tangchong Kuang , Yudong Gu , Xiangxiang Ren , Xufang Li , He Gao , Zhengwei Li , Congzhan Liu

Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) because lower SQUID inductance…

Instrumentation and Detectors · Physics 2020-01-29 S. Ruffieux , A. Kalaboukhov , M. Xie , M. Chukharkin , C. Pfeiffer , S. Sepehri , J. F. Schneiderman , D. Winkler

The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We…

Instrumentation and Detectors · Physics 2017-02-20 Jan-Hendrik Storm , Peter Hömmen , Dietmar Drung , Rainer Körber

The transport properties of a YBa$_2$Cu$_3$O$_{7-\delta}$ superconducting quantum interference device (SQUID) based on grooved Dayem bridge weak links are studied as a function of temperature: at high temperatures…

We have employed a feedback cooling scheme, which combines high-frequency mixing with digital signal processing. The frequency and damping rate of a 2 MHz micromechanical resonator embedded in a dc SQUID are adjusted with the feedback, and…

Mesoscale and Nanoscale Physics · Physics 2012-03-16 M. Poot , S. Etaki , H. Yamaguchi , H. S. J. van der Zant

We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop…

Mesoscale and Nanoscale Physics · Physics 2016-01-08 Andrea Vinante

We demonstrate a straightforward approach to integrating a magnetic field into a low-temperature scanning tunneling microscope (STM) by adhering an NdFeB permanent magnet to a magnetizable sample plate. To render our magnet concept…

We have developed a mini-coil pulsed magnet system with direct optical access, ideally suited for nonlinear and ultrafast spectroscopy studies of materials in high magnetic fields up to 30 T. The apparatus consists of a small coil in a…

Mesoscale and Nanoscale Physics · Physics 2014-02-11 G. Timothy Noe , Hiroyuki Nojiri , Joseph Lee , Gary L. Woods , Jean Leotin , Junichiro Kono

We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…

Superconductivity · Physics 2009-11-13 L. V. Levitin , R. G. Bennett , A. Casey , B. P. Cowan , C. P. Lusher , J. Saunders , D. Drung , Th. Schurig

Piezo-driven rotator is convenient for tilted magnetic field experiments due to its precise angle control. However, the rotator itself and the sample mounted on it are difficult to be cooled down because of extra heat leaks and presumably…

Mesoscale and Nanoscale Physics · Physics 2019-02-13 Pengjie Wang , Ke Huang , Jian Sun , Jingjin Hu , Hailong Fu , Xi Lin

Magnetic refrigeration at room temperature is of great interest due to a long-term goal of making refrigeration more energy-efficient, less noisy and free of any environmentally hostile materials. A refrigerator utilizing an active magnetic…

Materials Science · Physics 2012-09-19 K. K. Nielsen , R. Bjoerk , J. B. Jensen , C. R. H Bahl , N. Pryds , A. Smith , A. Nordentoft , J. Hattel

By employing highly sensitive millikelvin SQUID magnetometry, the magnitude of the Curie temperature as a function of the Mn concentration x is determined for thoroughly characterized Ga1-xMnxN. The interpretation of the results in the…

We present the main features of a home-built scanning tunneling microscope that has been attached to the mixing chamber of a dilution refrigerator. It allows scanning tunneling microscopy and spectroscopy measurements down to the base…

Superconductivity · Physics 2015-05-18 M. Marz , G. Goll , H. v. Loehneysen

Two modifications have been made to a miniature ceramic anvil high pressure cell (mCAC) designed for magnetic measurements at pressures up to 12.6 GPa in a commercial superconducting quantum interference (SQUID) magnetometer [N. Tateiwa et…

Materials Science · Physics 2015-06-15 Naoyuki Tateiwa , Yoshinori Haga , Tatsuma D Matsuda , Zachary Fisk , Shugo Ikeda , Hisao Kobayashi

We have characterized the temperature dependence of the flux threading dc SQUIDs cooled to millikelvin temperatures. The flux increases as 1/T as temperature is lowered; moreover, the flux change is proportional to the density of trapped…

Superconductivity · Physics 2009-11-13 S. Sendelbach , D. Hover , A. Kittel , M. Mück , John M. Martinis , R. McDermott

A Faraday force magnetometer is presented for measurements of magnetization at temperatures down to 100~mK and in magnetic fields up to 14~T. The specimen is mounted on a flexible cantilever forming a force-sensing capacitor in combination…

Materials Science · Physics 2020-07-22 Dominic Blosser , Leonardo Facheris , Andrey Zheludev

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only…

Mesoscale and Nanoscale Physics · Physics 2015-05-18 M. Hatridge , R. Vijay , D. H. Slichter , J. Clarke , I. Siddiqi

We report on the fabrication and characterization of microSQUID devices based on nanoscale vanadium/copper/vanadium Josephson weak links. Magnetically driven quantum interference patterns have been measured for temperatures in the 0.24 - 2…

Mesoscale and Nanoscale Physics · Physics 2013-09-06 Alberto Ronzani , Matthieu Baillergeau , Carles Altimiras , Francesco Giazotto