English
Related papers

Related papers: A Scintillator Tile-Fiber Preshower Detector for t…

200 papers

We propose extending parallel fiber dual readout calorimetry to tiles, more applicable to many future experimental requirements, with superior energy resolution. Monte Carlo (MC) studies indicate that a tile dual calorimeter including an…

Instrumentation and Detectors · Physics 2022-03-16 David Winn , Yasar Onel

The neutron detection efficiency of a sampling calorimeter made of 1 mm diameter scintillating fibers embedded in a lead/bismuth structure has been measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A significant…

A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are…

The high energy physics community has recently identified an $e^+e^-$ Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminosity LHC program at CERN.The moderate radiation levels…

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that uses plastic scintillator tiles read out by SiPMs. Among its innovative features are an ASIC-away-of-SiPM strategy for reducing cooling…

Instrumentation and Detectors · Physics 2023-11-27 Miguel Arratia , Bruce Bagby , Peter Carney , Jiajun Huang , Ryan Milton , Sebouh J. Paul , Sean Preins , Miguel Rodriguez , Weibin Zhang

Using scintillator tile technology several square meters of plastic scintillator are read out by only two photomultiplier with a time precision of about 1.5 nsec. Two examples are discussed to build a detector based on this technology to…

Instrumentation and Detectors · Physics 2016-09-08 J. Baehr , H. -J. Grabosch , V. Kantserov , H. Leich , R. Leiste , R. Nahnhauer

A prototype module for an International Linear Collider (ILC) detector was built, installed, and tested between 2006 and 2009 at CERN and Fermilab as part of the CALICE test beam program, in order to study the possibilities of extending…

Instrumentation and Detectors · Physics 2015-06-03 The CALICE Collaboration

We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as…

The CASTOR calorimeter is a detector covering the very forward region of the CMS experiment at the LHC. It surrounds the beam pipe with 14 longitudinal modules each of which consisting of 16 azimuthal sectors and allows to reconstruct…

Instrumentation and Detectors · Physics 2019-08-13 Dmytro Volyanskyy

The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…

High Energy Physics - Experiment · Physics 2007-05-23 E. C. Aschenauer , J. Baehr , V. Gapienko , B. Hoffmann , A. Kharchilava , H. Luedecke , R. Nahnhauer , R. Shanidze

This study reports the performance and light yield of 1% concentration water-based liquid scintillator (WbLS) deployed in a 1000-liter detector. A light yield of 99$\pm$15 photons per MeV is determined by comparing data with simulation.…

Instrumentation and Detectors · Physics 2023-12-19 Rong Zhao , Lindsey Bignell , David E. Jaffe , Richard Rosero , Minfang Yeh , Wei Wang , Aiwu Zhang

A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with…

Instrumentation and Detectors · Physics 2010-07-16 Adil Khan

The CALICE collaboration is developing highly granular electromagnetic and hadronic calorimeters for detectors at future energy frontier electron-positron colliders. After successful tests of a physics prototype, a technological prototype…

Instrumentation and Detectors · Physics 2022-10-03 CALICE Collaboration

Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam…

Instrumentation and Detectors · Physics 2017-12-05 Luis Peralta

The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the…

Instrumentation and Detectors · Physics 2012-08-27 The ATLAS Collaboration

Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating…

Instrumentation and Detectors · Physics 2014-06-17 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , T. Buanes , G. Eigen , Y. Mikami , N. K. Watson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , V. Uzhinskiy , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , G. Falley , K. Gadow , P. Göttlicher , C. Günter , B. Hermberg , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Feege , E. Garutti , I. Marchesinik , M. Ramilli , P. Eckert , T. Harion , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , P. D. Dauncey , A. -M. Magnan , V. Bartsch , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , N. Kirikova , V. Kozlov , P. Smirnov , Y. Soloviev , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , M. Szalay , M. Tesar , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , J. Rouëné , N. Seguin-Moreau , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , T. Takeshita , S. Uozumi , M. Götze , O. Hartbrich , J. Sauer , S. Weber , C. Zeitnitz

We have developed a novel tracking detector utilizing a water-based liquid scintillator (WbLS) for the accurate characterization of neutrino interactions on a water target. In this detector, the WbLS is optically segmented into small cells…

Instrumentation and Detectors · Physics 2025-12-10 Naoto Onda , Yuka Asano , Takashi Iida , Tatsuya Kikawa , Tsuyoshi Nakaya , Atsushi Tokiyasu , Daiki Wakabayashi

The intrinsic time structure of hadronic showers has been studied to evaluate its influence on the timing capability and on the required integration time of highly granular hadronic calorimeters in future collider experiments. The…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The D0 preshower detector consists of scintillator strips with embedded wavelength-shifting fibers, and a readout using Visible Light Photon Counters. The response to minimum ionizing particles has been tested with cosmic ray muons. We…

High Energy Physics - Experiment · Physics 2008-11-26 P. Baringer

Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in…

Instrumentation and Detectors · Physics 2020-06-15 CMS Collaboration