English
Related papers

Related papers: A Scintillator Tile-Fiber Preshower Detector for t…

200 papers

Results on diffraction obtained by the CDF Collaboration in Run I of the Fermilab Tevatron $\bar pp$ collider are reviewed. New results are reported on soft double diffraction and diffractive $J/\psi$ production. The CDF program for…

High Energy Physics - Experiment · Physics 2015-06-25 K. Goulianos

As a prototype detector for the SHiP Surrounding Background Tagger (SBT), we constructed a cell (120 cm x 80 cm x 25 cm) made from corten steel that is filled with liquid scintillator (LS) composed of linear alkylbenzene (LAB) and…

The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These…

Instrumentation and Detectors · Physics 2017-03-08 V. Ghenescu , Y. Benhammou

The SiPM-on-Tile technology for highly granular calorimeters, where small plastic scintillator tiles are directly read out with SiPMs, has been developed for the CALICE Analog Hadron Calorimeter, and has been adopted for parts of the…

Instrumentation and Detectors · Physics 2025-09-04 Fabian Hummer , Lorenz Emberger , Frank Simon

Losses from the proton and antiproton beams of the Fermilab Tevatron have been shown to produce a halo which contribute to backgrounds to physics signals in the Collider Detector at Fermilab (CDF). To provide a measure of the beam halo and…

High Energy Physics - Experiment · Physics 2014-11-17 Muge Karagoz Unel , Richard J. Tesarek

The hadronic shower longitudinal and lateral leakages and its effect on the pion response and energy resolution of iron-scintillator barrel hadron prototype calorimeter with longitudinal tile configuration with a thickness of 9.4 nuclear…

High Energy Physics - Experiment · Physics 2007-05-23 Y. A. Kulchitsky

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…

Instrumentation and Detectors · Physics 2014-07-24 CALICE Collaboration , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , M. A. Thomson , D. R. Ward , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , C. Carloganu , P. Gay , S. Manen , L. Royer , M. Tytgat , N. Zaganidis , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , A. Ebrahimi , G. Falley , K. Gadow , P. Goettlicher , C. Guenter , O. Hartbrich , B. Hermberg , S. Karstensen , F. Krivan , K. Krueger , B. Lutz , S. Morozov , V. Morgunov , C. Neubueser , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , E. Garutti , S. Laurien , S. Lu , I. Marchesini , M. Matysek , M. Ramilli , K. Briggl , P. Eckert , T. Harion , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , G. W. Wilson , K. Kawagoe , Y. Sudo , T. Yoshioka , P. D. Dauncey , M. Wing , F. Salvatore , E. Cortina Gil , S. Mannai , G. Baulieu , P. Calabria , L. Caponetto , C. Combaret , R. Della Negra , G. Grenier , R. Han , J-C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeur , M. Vander Donckt , Y. Zoccarato , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , F. Corriveau , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , D. Besson , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , J. Rouene , N. Seguin-Moreau , M. Anduze , V. Balagura , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , E. Guliyev , Y. Haddad , F. Magniette , G. Musat , M. Ruan , T. H. Tran , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , H. Ono , T. Takeshita , S. Uozumi , D. Jeans , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , M. Goetze , J. Sauer , S. Weber , C. Zeitnitz

A scalable 16-ch thermal neutron detection system has been developed in the framework of the upgrade of a neutron diffractometer. The detector is based on ZnS:${}^6$LiF scintillator with embedded WLS fibers which are read out with SiPMs. In…

Instrumentation and Detectors · Physics 2017-03-08 J. -B. Mosset , A. Stoykov , U. Greuter , A. Gromov , M. Hildebrandt , T. Panzner , N. Schlumpf

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

Polytetrafluoroethylene (PTFE), also known as Teflon, is a common material used in the construction of liquid xenon detectors due to its high reflectivity for the VUV scintillation light of xenon. We present transmission measurements of…

Instrumentation and Detectors · Physics 2020-09-10 Dominick Cichon , Guillaume Eurin , Florian Jörg , Teresa Marrodán Undagoitia , Natascha Rupp

A liquid scintillator (LS) is developed for the Taishan Antineutrino Observatory (TAO), a ton-level neutrino detector to measure the reactor antineutrino spectrum with sub-percent energy resolution by adopting Silicon Photomultipliers…

Instrumentation and Detectors · Physics 2021-07-07 Zhangquan Xie , Jun Cao , Yayun Ding , Mengchao Liu , Xilei Sun , Wei Wang , Yuguang Xie

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at a future Linear Collider. The hadron calorimeter uses small…

Instrumentation and Detectors · Physics 2019-08-13 Katja Seidel

The Pierre Auger Observatory has led to significant advances in our understanding of ultra-high-energy cosmic rays. These new insights have driven a major upgrade of the Observatory, known as AugerPrime, through which the experiment has…

Instrumentation and Methods for Astrophysics · Physics 2025-07-23 M. Conte

This study introduces chromatic calorimetry, a novel particle detection method that uses strategically layered scintillators with different emission wavelengths. This approach aims to enhance energy measurement by capturing particle…

Instrumentation and Detectors · Physics 2025-01-16 Devanshi Arora , Matteo Salomoni , Yacine Haddad , Vojtech Zabloudil , Michael Doser , Masaki Owari , Etiennette Auffray

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

We describe the design, construction and performance of the upgraded DO muon system for Run II of the Fermilab Tevatron collider. Significant improvements have been made to the major subsystems of the DO muon detector: trigger scintillation…

Instrumentation and Detectors · Physics 2009-09-29 The D0 Muon Group , V. M. Abazov

The SLD experiment at the Stanford Linear Accelerator Center had a significant gap in its muon tracking coverage, provided by the Warm Iron Calorimeter. Supplemental planes of limited streamer tube chambers were added to improve the…

High Energy Physics - Experiment · Physics 2007-05-23 V. O. Eschenburg
‹ Prev 1 4 5 6 7 8 10 Next ›