Related papers: Development of a two-dimensional virtual pixel X-r…
X-ray Free Electron Lasers (XFEL) are the most advanced pulsed x-ray sources. Their extraordinary pulse parameters promise unique applications. Indeed, several new methods have been developed at XFEL-s. However, no methods are known, which…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…
We report recent developments and tests with beams and cosmic rays of the gaseous photomultiplier (GasPM). The GasPM is a photosensor that combines a photocathode with the avalanche-multiplication mechanism of a resistive-plate chamber,…
Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…
Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…
A fast, hydrodynamic numerical model has been developed on the COMSOL Multi-physics platform to simulate the evolution and dynamics of charged particles in gaseous ionization detectors based on the Gaseous Electron Multipliers (GEM).…
NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling…
The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving…
Resonant inelastic X-ray scattering (RIXS) has become an important scientific tool. Nonetheless, conventional high-resolution RIXS measurements (<100 meV), especially in the soft x-ray range, require large and low-throughput grating…
For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type.…
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent…
In order to fully exploit the physics potential of the future high energy e+e- linear collider, a Vertex Tracker able to provide particle track extrapolation with very high resolution is needed. Hybrid Si pixel sensors are an attractive…
Ultrafast-optical-pump -- structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
A quadruple GEM detector has been assembled in a standalone configuration and operated using Ar and CO$_2$ gas mixtures in proportions of 70:30 and 90:10. Detailed performance study of the detector has been made by using $^{106}$Ru-Rh…
One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of…
The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
X-ray dark-field imaging visualises scattering from sample microstructure, and has found application in medical and security contexts. While most X-ray dark-field imaging techniques rely on masks, gratings, or crystals, recent work on the…
This paper presents the detailed simulation of a double-pixel structure for charged particle detection based on the 3D-trench silicon sensor developed for the TIMESPOT project and a comparison of the simulation results with measurements…