English
Related papers

Related papers: Virtual model of the differential pulse calorimete…

200 papers

Temperature is a major source of inaccuracy in high-sensitivity accelerometers and gravimeters. Active thermal control systems require power and may not be ideal in some contexts such as airborne or spaceborne applications. We propose a…

We present a technique based on high resolution imaging to measure the absolute temperature and the heating rate of a single ion trapped at the focus of a deep parabolic mirror. We collect the fluorescence light scattered by the ion during…

We have developed a new all-optical method to directly measure the pressure-volume-temperature (PVT) equation of state (EOS) of fluids and transparent solids in the diamond anvil high pressure cell by measuring the volume of the sample…

Other Condensed Matter · Physics 2024-08-16 J. E. Proctor , C. E. A. Robertson , L. J. Jones , J. Phillips , K. Watson , Y. Dabburi , B. Moss

The energy dependent thermoelectric response of a single molecule contains valuable information about its transmission function and its excited states. However, measuring it requires devices that can efficiently heat up one side of the…

Safety against thermal failures is crucial in battery systems. Real-time thermal diagnostics can be a key enabler of such safer batteries. Thermal fault diagnostics in large format pouch or prismatic cells pose additional challenges…

Systems and Control · Electrical Eng. & Systems 2021-09-14 Sara Sattarzadeh , Tanushree Roy , Satadru Dey

This article presents the Calorimetry - SimuF\'isica simulator, an interactive computational tool designed for teaching heat exchange processes. The simulator enables dynamic and audiovisual exploration of phenomena such as the heating of…

Physics Education · Physics 2025-06-05 Marco P. M. de Souza , Alex B. Siqueira

We report direct and absolute temperature measurements in a diode-end-pumped Yb:YAG crystal, using a calibrated infrared camera, with a 60-$\mu$m spatial resolution. The heat transfer coefficient has been measured, for the first time to our…

Using a time-resolved phonon absorption technique, we have measured the specific heat of a two-dimensional electron system in the fractional quantum Hall effect regime. For filling factors $\nu = 5/3, 4/3, 2/3, 3/5, 4/7, 2/5$ and 1/3 the…

Mesoscale and Nanoscale Physics · Physics 2009-11-11 F. Schulze-Wischeler , U. Zeitler , C. v. Zobeltitz , F. Hohls , D. Reuter , A. D. Wieck , H. Frahm , R. J. Haug

We demonstrate a blackbody radiation thermometer based on optically excited rubidium atoms in a vapor cell. The temperature measurement is fast, with statistical uncertainty as low as 0.1% in one second. We resolve temperature with a…

We present a space-time virtual element method for the discretization of the heat equation, which is defined on general prismatic meshes and variable degrees of accuracy. Strategies to handle efficiently the space-time mesh structure are…

Numerical Analysis · Mathematics 2023-11-13 Sergio Gómez , Lorenzo Mascotto , Ilaria Perugia

This paper presents the study and implementation of finite element method to find the temperature distribution in a rectangular cavity which contains a fluid substance. The fluid motion is driven by a sudden temperature difference applied…

Fluid Dynamics · Physics 2013-09-16 Christian Naa , Suprijadi

Nanomagnetic hyperthermia (NMH) is intensively studied with the prospect of cancer therapy. A major challenge is to determine the dissipated power during in vivo conditions and conventional methods are either invasive or inaccurate. We…

Medical Physics · Physics 2018-08-27 I. Gresits , Gy. Thuróczy , O. Sági , B. Gyüre-Garami , B. G. Márkus , F. Simon

We discuss work performed on a quantum two-level system coupled to multiple thermal baths. To evaluate the work, a measurement of photon exchange between the system and the baths is envisioned. In a realistic scenario, some photons remain…

Heating and cooling load calculation based on dynamic models is widely used in simulation software and it is the method recommended by ASHRAE and CEN. The principle is to make the heat balance for the air volume of a room space considered…

Systems and Control · Electrical Eng. & Systems 2022-03-18 Christian Ghiaus

Temperature Modulated calorimetry is widely used but still raises some fundamental questions. In this paper we study a model system as a test sample to address some of them. The model has a nontrivial spectrum of relaxation times. We…

Statistical Mechanics · Physics 2022-04-04 Jean-Luc Garden , Michel Peyrard

The recent development of the calculation of specific heat ($C$) of liquids and glasses by first-principles molecular dynamics (MD) simulations is reviewed. Liquid and glass states have common properties in that there is no periodicity and…

Disordered Systems and Neural Networks · Physics 2025-08-29 K. Shirai

The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two…

Instrumentation and Detectors · Physics 2016-07-13 Z. Deng , Y. Li , Y. Wang , Q. Yue , Z. Yang , J. Apostolakis , G. Folger , C. Grefe , V. Ivantchenko , A. Ribon , V. Uzhinskiy , D. Boumediene , C. Carloganu , V. Français , G. Cho , D-W. Kim , S. C. Lee , W. Park , S. Vallecorsa , S. Cauwenbergh , M. Tytgat , A. Pingault , N. Zaganidis , E. Brianne , A. Ebrahimi , K. Gadow , P. Göttlicher , C. Günter , O. Hartbrich , B. Hermberg , A. Irles , F. Krivan , K. Krüger , J. Kvasnicka , S. Lu , B. Lutz , V. Morgunov , C. Neubüser , A. Provenza , M. Reinecke , F. Sefkow , S. Schuwalow , H. L. Tran , E. Garutti , S. Laurien , M. Matysek , M. Ramilli , S. Schroeder , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , K. Kawagoe , H. Hirai , Y. Sudo , T. Suehara , H. Sumida , T. Yoshioka , E. Cortina Gil , S. Mannai , V. Buridon , C. Combaret , L. Caponetto , R. Eté , G. Garillot , G. Grenier , R. Han , J. C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , J. Berenguer Antequera , E. Calvo Alamillo , M. -C. Fouz , J. Marin , J. Puerta-Pelayo , A. Verdugo , M. Chadeeva , M. Danilov , M. Gabriel , P. Goecke , C. Kiesling , N. vanderKolk , F. Simon , M. Szalay , S. Bilokin , J. Bonis , P. Cornebise , F. Richard , R. Pöschl , J. Rouëné , A. Thiebault , D. Zerwas , M. Anduze , V. Balagura , K. Belkadhi , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , Y. Haddad , F. Magniette , M. Ruan , M. Rubio-Roy , K. Shpak , H. Videau , D. Yu , S. Callier , S. Conforti di Lorenzo , F. Dulucq , G. Martin-Chassard , Ch. de la Taille , L. Raux , N. Seguin-Moreau , K. Kotera , H. Ono , T. Takeshita , F. Corriveau

The lithium vapor box divertor is a concept for handling the extreme divertor heat fluxes in magnetic fusion devices. In a baffled slot divertor, plasma interacts with a dense cloud of Li vapor which radiates and cools the plasma, leading…

Instrumentation and Detectors · Physics 2018-08-10 Jacob A Schwartz , Eric D Emdee , M A Jaworski , R J Goldston

A modified AC method based on micro-fabricated heater and resistive thermometers has been applied to measure the thermopower of microscale samples. A sinusoidal current with frequency {\omega} is passed to the heater to generate an…

Instrumentation and Detectors · Physics 2018-11-14 Hanfu Wang , Fanglong Yang , Yanjun Guo , Kaiwu Peng , Dongwei Wang , Weiguo Chu , Shuqi Zheng

Controlling and measuring the temperature in different devices and platforms that operate in the quantum regime is, without any doubt, essential for any potential application. In this review, we report the most recent theoretical…

Quantum Physics · Physics 2019-07-04 Mohammad Mehboudi , Anna Sanpera , Luis A. Correa