English
Related papers

Related papers: Virtual model of the differential pulse calorimete…

200 papers

A new method of absolute heat capacity measurement was developed in the Department of Biological Systems Physics at the E. Andronikashvili Institute of Physics, Georgian Academy of Sciences. This is the method of absolute heat capacity…

Biological Physics · Physics 2007-05-23 G. Tvauri , N. Bakradze , E. Kiziria

We present a new type of calorimeter in which we couple an unknown heat capacity with the aid of Peltier elements to an electrical circuit. The use of an electrical inductance and an amplifier in the circuit allows us to achieve autonomous…

Instrumentation and Detectors · Physics 2015-05-28 Olaf Bossen , Andreas Schilling

The work gives the estimation of the heat capacity jump at melting in water of collagen fibers of rat tail tendons. The measurements were carried out by an original calorimetric system designed by the authors, which in contrast to modern…

Biological Physics · Physics 2012-06-19 M. Nadareishvili , T. Burjanadze. K. Kvavadze , N. Kekelidze , E. Kiziria , E. Gelagutashvili

A novel approach to calibrate the sensitivity of a differential thermometer, consisting of several thermocouples connected in series (thermopile), has been developed. The goal of this method is to increase the accuracy of small temperature…

Instrumentation and Detectors · Physics 2020-12-24 Tim Prangemeier , Iman Nejati , Andreas Müller , Philip Endres , Mario Fratzl , Mathias Dietzel

The investigations of low-temperature heat capacity in pure and impurity doped high temperature superconductors have been performed by high-precision pulsed differential scanning calorimeter, providing the measurements of heat capacities…

Superconductivity · Physics 2012-10-09 M. M. Nadareishvili , K. A. Kvavadze , N. E. Hussey , A. J. Shengelaya , S. J. Tsakadze , J. Ramsden

A differential, membrane-based nanocalorimeter for general specific heat studies of very small samples, ranging from 0.5 mg to sub-{\mu}g in mass, is described. The calorimeter operates over the temperature range from above room temperature…

Instrumentation and Detectors · Physics 2012-08-20 S. Tagliati , V. M. Krasnov , A. Rydh

Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz to 10 MHz), opening up the possibility of new methods to detect and characterize…

Materials Science · Physics 2017-04-26 Zachary M. Geballe , Viktor V. Struzhkin , Andrew Townley , Raymond Jeanloz

A high resolution non-adiabatic method for measuring the heat capacity ($C_v$) of bulk samples of condensable gases in the range 7.5-70 K is described. In this method $C_v$ is evaluated by directly comparing the heating and cooling rates of…

Materials Science · Physics 2009-10-31 S. Pilla , J. A. Hamida , N. S. Sullivan

This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…

Instrumentation and Detectors · Physics 2016-01-11 Elysée Obame Ndong , Olivier Gallot-Lavallée , Frédéric Aitken

We provide the theoretical basis of calorimetry for a class of active particles subject to thermal noise. Simulating AC-calorimetry, we numerically evaluate the heat capacity of run-and-tumble particles in double-well and in periodic…

Statistical Mechanics · Physics 2023-05-24 Pritha Dolai , Christian Maes , Karel Netočný

This paper presents LongHCPulse: software which enables heat capacity to be collected on a Quantum Design PPMS using a long-pulse method. This method, wherein heat capacity is computed from the time derivative of sample temperature over…

Instrumentation and Detectors · Physics 2018-08-03 Allen Scheie

We have developed a new calorimeter for measuring thermodynamic properties in pulsed magnetic fields. An instrumental design is described along with the construction details including the sensitivity of a RuO2 thermometer. The operation of…

Instrumentation and Detectors · Physics 2021-04-14 Shusaku Imajo , Chao Dong , Akira Matsuo , Koichi Kindo , Yoshimitsu Kohama

To achieve accurate results in nanocalorimetry a detailed analysis and understanding of the behavior of the calorimetric system is required. There are especially two system-related aspects that should be taken in consideration: the…

Other Condensed Matter · Physics 2012-03-12 S. Tagliati , A. Rydh

Motivated by the recent development of fast and ultra-sensitive thermometry in nanoscale systems, we investigate quantum calorimetric detection of individual heat pulses in the sub-meV energy range. We propose a hybrid superconducting…

Mesoscale and Nanoscale Physics · Physics 2018-11-28 F. Brange , P. Samuelsson , B. Karimi , J. P. Pekola

Heat capacity measurements using the ac steady state method are often considered difficult to provide absolute accuracy. By adjusting the working frequency to maintain a constant phase and using the phase information to obtain the heat…

Superconductivity · Physics 2015-06-04 S. Tagliati , A. Rydh

Numerical simulations of heat transport in diamond anvil cells reveal a possibility for absolute measurements of specific heat via high-frequency modulation calorimetry. Such experiments could reveal and help characterize temperature-driven…

Materials Science · Physics 2017-04-26 Zachary M. Geballe , Gilbert W. Collins , Raymond Jeanloz

The non-equilibrium process due to irreversible heat exchanges occurring during a temperature modulated differential scanning calorimetry experiment is investigated in detail. This enables us to define an experimental frequency dependent…

Other Condensed Matter · Physics 2008-08-21 Jean-Luc Garden , Jacques Richard , Yasuo Saruyama

Common thermal anemometers (hot-wire, hot-film, or similar) are based on the thermal equilibrium between the electrical power heating the sensor and the convection of the ambient medium cooling the sensor. The response times of such…

Instrumentation and Detectors · Physics 2023-08-08 Holger Nobach

We report an experimental setup for simultaneously measuring specific heat and thermal conductivity in feedback-controlled pulsed magnetic fields of 50 msec duration at cryogenic temperatures. A stabilized magnetic field pulse obtained by…

Recent developments of the AC-calorimetric technique adapted for the needs of high pressure experiments are discussed. A semi-quantitative measurement of the specific heat with a Bridgman-type of pressure cell as well as a diamond anvil…

Strongly Correlated Electrons · Physics 2015-06-24 Heribert Wilhelm
‹ Prev 1 2 3 10 Next ›