English
Related papers

Related papers: A two dimensional position sensitive gas chamber w…

200 papers

An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…

Instrumentation and Detectors · Physics 2023-05-03 L. M. S. Margato , G. Canezin , A. Morozov , A. Blanco , J. Saraiva , L. Lopes , P. Fonte

A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…

Instrumentation and Detectors · Physics 2015-06-19 Y. Haddad , M. Ruan , V. Boudry

We report results obtained during the characterization of a commercial front-illuminated progressive scan interline transfer CCD camera. We demonstrate that the unmodified camera operates successfully in temperature and pressure conditions…

Accurate range verification of carbon ion beams is critical for the precision and safety of charged particle radiotherapy. In this study, we evaluated the feasibility of using a parallel-plate ionization chamber for real-time, time-based…

The search for neutrinoless double beta decay ($0\nu\beta\beta$) remains one of the most compelling experimental avenues for the discovery in the neutrino sector. Electroluminescent gas-phase time projection chambers are well suited to…

Instrumentation and Detectors · Physics 2023-08-04 NEXT Collaboration , N. K. Byrnes , I. Parmaksiz , C. Adams , J. Asaadi , J Baeza-Rubio , K. Bailey , E. Church , D. González-Díaz , A. Higley , B. J. P. Jones , K. Mistry , I. A. Moya , D. R. Nygren , P. Oyedele , L. Rogers , K. Stogsdill , H. Almazán , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , S. Ayet , C. D. R. Azevedo , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , S. Bounasser , S. Cárcel , J. V. Carrión , S. Cebrián , L. Cid , C. A. N. Conde , T. Contreras , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , M. Elorza , J. Escada , R. Esteve , A. Fahs , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , E. D. C. Freitas , Z. Freixa , J. Generowicz , A. Goldschmidt , J. J. Gómez-Cadenas , R. González , J. Grocott , R. Guenette , J. Haefner , K. Hafidi , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , J. Ho , P. Ho , Y. Ifergan , L. Labarga , L. Larizgoitia , P. Lebrun , F Lopez , D. Lopez Gutierrez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , G. Martínez-Lema , M. Martínez-Vara , Z. E. Meziani , R. L. Miller , F. Monrabal , C. M. B. Monteiro , F. J. Mora , J. Muñoz Vidal , K. E. Navarro , P. Novella , A. Nuñez , E. Oblak , M. Odriozola-Gimeno , J. Palacio , B. Palmeiro , A. Para , J Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , J. Rodríguez , C. Rogero , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , A. Simón , S. R. Soleti , M. Sorel , C. Stanford , J. M. R. Teixeira , J. F. Toledo , J. Torrent , A. Usón , J. F. C. A. Veloso , T. T. Vuong , J. Waiton , J. T. White

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…

Instrumentation and Detectors · Physics 2015-10-28 S. R. Mirfayzi

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the…

Accelerator Physics · Physics 2023-01-25 F Osswald , T Durand , M Heine , J Michaud , F Poirier , J C Thomas , E Traykov

We report a systematic study of charge distribution dependency of CMS Resistive Plate Chamber (RPC) on gap thickness. Prototypes of double-gap RPCs with six different gap thickness ranging from from 1.0 to 2.0 mm in 0.2-mm steps have been…

Instrumentation and Detectors · Physics 2016-12-21 Sung K. Park , Min Ho Kang , Kyongsei Lee

Gaseous Time Projection Chambers with Optical Readout are sensitive detectors suitable for 3D measurement of low-energy O(1 keV) particles and are proposed for detecting rare events such as Dark Matter particle interactions. The CYGNO…

This paper describes a new method for optical readout of Time Projection Chambers (TPCs), based on the Linearly Graded Silicon Photomultiplier (LG-SiPM). This is a single photon-sensitive detector with excellent timing and 2D position…

Instrumentation and Detectors · Physics 2020-12-15 A. Gola , K. Majumdar , G. Casse , K. Mavrokoridis , S. Merzi , L. Parsons Franca

Graphene's linear bandstructure and two-dimensional density of states provide an implicit advantage for sensing charge. Here, these advantages are leveraged in a deeply depleted graphene-oxide-semiconductor (D2GOS) junction detector…

Time Projection Chambers (TPCs) with charge readout via micro pattern gaseous detectors can provide detailed measurements of charge density distributions. We here report on measurements of alpha particle tracks, using a TPC where the drift…

Instrumentation and Detectors · Physics 2015-12-09 P. M. Lewis , S. E. Vahsen , M. T. Hedges , I. Jaegle , I. S. Seong , T. N. Thorpe

In a CMOS image sensor pixel, fast and complete charge transfer from pinned photodiode (PPD) is desired and necessary in some applications. In special cases such as time-of-flight imaging or large pinned photodiodes, the PPD potential well…

Applied Physics · Physics 2022-05-04 Hamzeh Alaibakhsh , Mohammad Azim Karami

Image sensors with nondestructive charge readout provide single-photon or single-electron sensitivity, but at the cost of long readout times. We present a smart readout technique to allow the use of these sensors in visible-light and other…

Instrumentation and Methods for Astrophysics · Physics 2021-12-15 Fernando Chierchie , Guillermo Fernandez Moroni , Leandro Stefanazzi , Eduardo Paolini , Javier Tiffenberg , Juan Estrada , Gustavo Cancelo , and Sho Uemura

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a…

Instrumentation and Detectors · Physics 2016-08-03 Bin-Xiang Qi , Shu-Bin Liu , Heng Ji , Zhong-Tao Shen , Si-Yuan Ma , Hong-Bang Liu , Wen-Qian Huang , Qi An

We demonstrate a simple stacked scheme that enables absorption imaging through a hole in the surface of a grating magneto-optical trap (GMOT) chip, placed immediately below a micro-fabricated vacuum cell. The imaging scheme is capable of…

There are several applications which require high position resolution UV imaging. For these applications we have developed and successfully tested a new version of a 2D UV single photon imaging detector based on a microgap RPC. The main…

Instrumentation and Detectors · Physics 2009-11-11 P. Fonte , T. Francke , N. Pavlopoulos , V. Peskov , I. Rodionov

The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…

Instrumentation and Detectors · Physics 2008-11-26 M. S. Dixit , A. Rankin

This paper presents the results of a study of the response of a test CMOS sensor with a radiation tolerant pixel cell design to 80 keV and 100 keV electrons. The point spread function is measured to be (13.0+/- 1.7) microns at 100 keV and…

Instrumentation and Detectors · Physics 2009-06-25 Marco Battaglia , Devis Contarato , Peter Denes , Dionisio Doering , Velimir Radmilovic
‹ Prev 1 3 4 5 6 7 10 Next ›