English
Related papers

Related papers: A two dimensional position sensitive gas chamber w…

200 papers

An X-ray detector will be presented that is the combination of a segmented ionization chamber featuring one-dimensional spatial resolution integrated with an intelligent ADC front-end, multi DSP processing and embedded PC platform. This…

Instrumentation and Detectors · Physics 2010-01-26 Francesco Voltolina , Ralf H. Menk , Sergio Carrato

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…

Instrumentation and Detectors · Physics 2022-11-22 Y. X. Ding , X. Y. Xie , J. X. Li , K. L. Han , Y. J. Sun

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

This paper presents a first study of the performance of a novel 2D position-sensitive microstrip detector, where the resistive charge division method was implemented by replacing the metallic electrodes with resistive electrodes made of…

Instrumentation and Detectors · Physics 2015-05-28 D. Bassignana , M. Fernandez , R. Jaramillo , M. Lozano , F. J. Munoz , G. Pellegrini , D. Quirion , I. Vila

A new readout technique was developed with the primary aim of keeping the number of channels in the front-end electronics as low as possible when scaling up the sensitive area of a Resistive Plate Chamber (RPC). The readout method here…

Instrumentation and Detectors · Physics 2024-07-16 João Pedro de Carvalho Saraiva , Alberto Blanco Castro

We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron…

Instrumentation and Detectors · Physics 2008-11-26 A. Bamberger , K. Desch , U. Renz , M. Titov , N. Vlasov , P. Wienemann , A. Zwerger

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

Instrumentation and Detectors · Physics 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

In this work a combination of an ionization chamber with one-dimensional spatial resolution and a MicroCAT structure will be presented. The combination between gas gain operations and integrating front-end electronics yields a dynamic range…

Instrumentation and Detectors · Physics 2015-05-18 Ralf-Hendrik Menk , Heinz Amenitsch , Fulvia Arfelli , Sigrid Bernstorff , Hans Juergen Besch , Francesco Voltolina

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

A position sensitive thin gap chamber has been developed. The position resolution was measured using the cosmic muons. This paper presents the structure of this detector, position resolution measurement method and results.

Instrumentation and Detectors · Physics 2015-06-17 Yanyan Du , Tongye Xu , Ruobin Shao , Xu Wang , Chengguang Zhu

We report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs). Unambiguous 3D charge readout was…

Instrumentation and Detectors · Physics 2018-10-12 D. A. Dwyer , M. Garcia-Sciveres , D. Gnani , C. Grace , S. Kohn , M. Kramer , A. Krieger , C. J. Lin , K. B. Luk , P. Madigan , C. Marshall , H. Steiner , T. Stezelberger

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…

Instrumentation and Detectors · Physics 2008-11-26 K. Boudjemline , M. S. Dixit , J. -P. Martin , K. Sachs

Position sensitive detectors based on gaseous scintillation proportional counters with Anger-type readout are being used in several research areas such as neutron detection, search for dark matter and neutrinoless double beta decay. Design…

Instrumentation and Detectors · Physics 2016-01-20 L. Pereira , L. M. S. Margato , A. Morozov , V. Solovov , F. A. F. Fraga

We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters…

Instrumentation and Detectors · Physics 2021-03-19 Jakub M. Ratajczak

The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of…

Instrumentation and Detectors · Physics 2016-08-25 S. Stephenson , J. Haefner , Q. Lin , K. Ni , K. Pushkin , R. Raymond , M. Schubnell , N. Shutty , G. Tarlé , C. Weaverdyck , W. Lorenzon

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the…

Instrumentation and Detectors · Physics 2015-06-26 R. Bellazzini , F. Angelini , L. Baldini , F. Bitti , A. Brez , L. Latronico , M. M. Massai , M. Minuti , N. Omodei , M. Razzano , C. Sgro , G. Spandre , E. Costa , P. Soffitta

A time projection chamber (TPC) based on a gaseous chamber with micro pixel electrodes (micro-PIC) has been developed for measuring three-dimensional tracks of charged particles. The micro-PIC with a detection area of 10 cm square consists…

High Energy Physics - Experiment · Physics 2015-06-25 H. Kubo , K. Miuchi , T. Nagayoshi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched…

A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the…

Instrumentation and Detectors · Physics 2022-12-21 Alexander Deisting
‹ Prev 1 2 3 10 Next ›