Related papers: Low noise temperature control : application to an …
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm…
We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8$\, \rm Ghz$. We exclude axion models with two photon coupling…
Superconducting radio-frequency (SRF) thin film cavities on copper substrates are employed in several particle accelerators. However, these SRF cavities historically featured a progressive performance degradation with the accelerating field…
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the…
We describe the construction and operation of a two-channel noise detection system for measuring power and cross spectral densities of current fluctuations near 2 MHz in electronic devices at low temperatures. The system employs cryogenic…
Single pressure refractive index gas thermometry (SPRIGT) is a novel primary thermometry, jointly developed by TIPC of CAS in China and LNE-Cnam in France. To realize a competitive uncertainty of 0.25 mK for thermodynamic temperature…
Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in…
Low-noise temperature measurements at frequencies in the milli-Hertz range are needed in the LISA and LISA PathFinder (LPF). The required temperature stability for LISA is around 10 uK/sqrt(Hz) at frequencies down to 0.1 mHz. In this paper…
Nanoscale electromechanical coupling provides a unique route towards control of mechanical motions and microwave fields in superconducting cavity electromechanical devices. Though their successes in utilizing the optomechanical or…
Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended…
The frequency stability of lasers is limited by thermal noise in state-of-the-art frequency references. Further improvement requires operation at cryogenic temperature. In this context, we investigate a fiber-based ring resonator. Our…
We present a noise estimation and subtraction algorithm capable of increasing the sensitivity of heterodyne laser interferometers by one order of magnitude. The heterodyne interferometer is specially designed for dynamic measurements of a…
Low capacitance, large volume, high purity germanium (HPGe) radiation detectors have been successfully employed in low-background physics experiments. However, some physical processes may not be detectable with existing detectors whose…
We implemented a low noise current preamplifier for the readout of resistive bolometers. We tested the apparatus on thermometer resistances ranging from 10 Ohm to 500 Mohm. The use of current preamplifier overcomes constraints introduced by…
Current state-of-the-art superconducting microwave qubits are cooled to extremely low temperatures to avoid sources of decoherence. Higher qubit operating temperatures would significantly increase the cooling power available, which is…
Squeezing the quadrature noise of a harmonic oscillator used as a sensor can enhance its sensitivity in certain measurment schemes. The canonical approach, based on parametric modulation of the oscillation frequency, is usually limited to a…
High-sensitivity long-wave infrared (LWIR) detection is crucial for observing weak thermal radiation. Recently, the Poisson bolometer has been proposed as a fundamentally new platform for uncooled infrared detection. In contrast to…
Fast feedback from cryogenic electrical characterization measurements is key for the development of scalable quantum computing technology. At room temperature, high-throughput device testing is accomplished with a probe-based solution,…
We report on the noise of a lumped element Direct Current Superconducting Quantum Interference Device amplifier. We show that the noise temperature in the 4 GHz-8 GHz range over ranges of 10's of MHz is below 1 kelvin (three photons of…
Ponderomotive squeezing of light, where a mechanical oscillator creates quantum correlations between the phase and amplitude of the interacting light field, is a canonical signature of the quantum regime of optomechanics. At room…