English
Related papers

Related papers: Potential of RPCs for tracking

200 papers

A new type of resistive plate chamber (RPC) is under development using thin-film resistive electrodes based on diamond-like carbon (DLC). Planned to be put on the path of high-intensity low-momentum muon beam of the MEG II experiment, this…

Instrumentation and Detectors · Physics 2022-12-21 Atsushi Oya , Kei Ieki , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Kensuke Yamamoto

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…

Instrumentation and Detectors · Physics 2009-11-07 P. Fonte , V. Peskov

We developed a novel design of a Micro Pixel Chamber ($\mu$-PIC) with resistive electrodes for a charged-particle-tracking detector in high-rate applications. Diamond-Like Carbon (DLC) thin film is used for the cathodes. The resistivity can…

Instrumentation and Detectors · Physics 2020-01-08 Fumiya Yamane , Atsuhiko Ochi , Kohei Matayoshi , Keisuke Ogawa , Yusuke Ishitobi

The conventional readout method of the RPC detector uses two sets of orthogonal readout strips placed at the both sides of the gas gap to collect signals of opposite polarities to obtain space points. A new readout method utilizing the…

Instrumentation and Detectors · Physics 2022-11-22 Y. X. Ding , X. Y. Xie , J. X. Li , K. L. Han , Y. J. Sun

We broach a seldom-discussed topic in precision metrology; how subtle errors in calibration processes are discovered and remedied. We examine a case study at the National Physical Laboratory (NPL), UK, involving the calibration of DC…

Instrumentation and Detectors · Physics 2025-12-03 Stephen Giblin

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

Mass characterisation of emerging memory devices is an essential step in modelling their behaviour for integration within a standard design flow for existing integrated circuit designers. This work develops a novel characterisation platform…

The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…

Instrumentation and Detectors · Physics 2020-01-29 R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento , A. Rocchi

This note describes a study on the momentum resolution of the TPC-based central tracker design which will be included in the ECFA/DESY conceptual design report (CDR) for the proposed DESY 500 GeV electron-positron linear collider. The study…

High Energy Physics - Experiment · Physics 2007-05-23 Bruce J. King

The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…

Instrumentation and Detectors · Physics 2015-12-09 G. Belli , M. Gabusi , G. Musitelli , R. Nardò , S. P. Ratti , A. Tamborini , P. Vitulo

The Multi-gap Resistive Plate Chamber (MRPC) is an advanced form of Resistive Plate Chamber (RPC) detector where the gas gap is divided into sub-gaps. MRPCs are known for their good time resolution and detection efficiency for charged…

Instrumentation and Detectors · Physics 2018-08-15 Rajesh Ganai , Mitali Mondal , Shaifali Mehta , Zubayer Ahammed , Subhasis Chattopadhyay

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium…

In this study we report the results of a systematic study of the gain, rate and the position resolution limits of various micropattern gaseous detectors. It was found that at low rates (<1 Hz/mm^2) each detector has it own gain limit, which…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte

We have developed novel impedance standards based on thin-film surface-mount-device (SMD) resistors. Due to the small dimensions of such resistors, the quantities determining their frequency dependence are very small and can be either…

Instrumentation and Detectors · Physics 2024-08-16 Jürgen Schurr , Rolf H. Judaschke , Shakil A. Awan

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

This paper presents a new design of the RETGEM (Resistive Electrode Thick GEM) based on electrodes made of a polyvinylchloride material (PVC). Our device can operate with gains of 10E5 as a conventional TGEM at low counting rates and as RPC…

Instrumentation and Detectors · Physics 2009-11-26 V. I. Razin , B. M. Ovchinnikov , A. I. Reshetin , S. N. Filippov

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes