Related papers: Wire Scanners for Small Emittance Beam Measurement…
A new approach to the technique of scanning by wires is developed. Novelty of the method is that the wire heating quantity is used as a source of information about the number of interacting particles. To increase the accuracy and…
The coaxial wire method is a common and appreciated technique to assess the beam coupling impedance of an accelerator element from scattering parameters. Nevertheless, the results obtained from wire measurements could be inaccurate due to…
We analyze the transmission and reflection of the electromagnetic wave calculated from transfer matrix simulations of periodic arrangements of thin metallic wires. The effective permittivity and the absorption is determined. Their…
The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary…
A non-invasive, compact laserwire system has been developed to measure the transverse emittance of an H- beam and has been demonstrated at the new LINAC4 injector for the LHC at CERN. Light from a low power, pulsed laser source is conveyed…
We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an…
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…
By scanning a fine open-ended coaxial probe above an operating microwave device, we image local electric fields generated by the device at microwave frequencies. The probe is sensitive to the electric flux normal to the face of its center…
Atomic force microscopy (AFM) is a well-known tool for studying surface roughness and to collect depth information about features on the top atomic layer of samples. By combining secondary ion mass spectroscopy (SIMS) with focused ion beam…
X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV…
The ATLAS Forward Physics (AFP) project plans to install 3D silicon pixel detectors about 210 m away from the interaction point and very close to the beamline (2-3 mm). This implies the need of slim edges of about 100-200 $\mu$m width for…
A fast neutron spectrometer consisting of segmented plastic scintillator and He-3 proportional counters was constructed for the measurement of neutrons in the energy range 1 MeV to 200 MeV. We discuss its design, principles of operation,…
We report on the fabrication and characterization of single-photon-sensitive WSi superconducting detectors with wire widths from 1 {\mu}m to 3 {\mu}m. The devices achieve saturated internal detection efficiency at 1.55 {\mu}m wavelength and…
We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 micron apertures, crossed by 25 micron anode strips to which it is attached by 50 micron kapton spacers. In the region where…
2D and 4D transverse phase-space of a low-energy ion-beam is measured with two of the most common emittance scanners. The article covers the description of the installation, the setup, the settings, the experiment and the benchmark of the…
A tightly focused laser beam (laser wire) is used for measurement of transverse electron beam sizes in storage rings and linear colliders. It is assumed that the laser beam does nothing with the electron beam except Compton scatterings…
The pepper-pot method is a widely used technique, originally proposed for measuring the emittance of space-charge-dominated electron beams from radio-frequency photoinjectors. With recent advances in producing high-brightness electron beams…
The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the…
We show that measured optical transmittance of an ultra thin gas depends on the detector size. To this end we conducted an experiment that compares transmittances measured in parallel with a pair of detectors with different diameters…
This report presents bunch length and energy spread measurements performed in April 2000 at the ATF Damping Ring, at KEK. Measurements were performed with the beam on and then off the linear (difference) coupling resonance. Due to strong…