Related papers: Wire Scanners for Small Emittance Beam Measurement…
We have developed Water Vapour Radiometers (WVRs) for the Australia Telescope Compact Array (ATCA) that are capable of determining signal path length fluctuations by virtue of measuring small temperature fluctuations in the atmosphere using…
Three Gas-Electron-Multiplier tracking detectors with an active area of 10 cm x 10 cm and a two-dimensional, laser-etched orthogonal strip readout have been tested extensively in particle beams at the Meson Test Beam Facility at Fermilab.…
The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from…
We study the effects of specimen mistilt on the picometer-scale measurement of local structure by combing experiment and simulation in annular bright-field scanning transmission electron microscopy (ABF-STEM). A relative distance…
We describe an algorithm which has been developed to extract fine granularity information from an electromagnetic calorimeter with strip-based readout. Such a calorimeter, based on scintillator strips, is being developed to apply particle…
A scanning force microscope with a base temperature below 300 mK is used for measuring the local electron density of a two-dimensional electron gas embedded in an Ga[Al]As heterostructure. At different separations between AFM tip and…
A photogrammetric method of stress analysis has been developed to test thin, nonstandard windows designed for hydrogen absorbers, major components of a muon cooling channel. The purpose of the absorber window tests is to demonstrate an…
This letter proposes a new method based on ultrafast high energy electron radiography to diagnose transient electromagnetic field. For the traditional methods, large scattering from matter will increase the uncertainty of measurement, but…
A novel emittance meter has been developed to measure the four-dimensional, transverse phase-space distribution of a low-energy ion beam using the pepper-pot technique. A characteristic feature of this instrument is that the pepper-pot…
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire…
A one-coordinate gaseous detector of soft X-ray photons for wide-angle X-ray scattering (WAXS) studies is being developed. The detector operates in counting mode and is based on multi-stage Gas Electron Multiplier(GEM). Full size detector…
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption spectroscopy and X-ray diffraction to provide chemically specific structural information of materials. It operates in the energy range 2.4-27 keV by using a…
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications…
Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited…
Laser wakefield acceleration (LWFA) in a gas cell target separating injection and acceleration section has been investigated to produce high-quality electron beams. A detailed study has been performed on controlling the quality of…
The half-size prototype of the multi wire drift chamber (MWDC) for the cooling storage ring (CSR) external-target experiment (CEE) was assembled and tested in 350 MeV/u Kr+Fe reactions on the heavy ion research facility in Lanzhou (HIRFL).…
Weak measurement (WM) with state pre- and post-selection can amplify otherwise undetectable small signals and thus promise great potentials in precision measurements. Although frequency measurements offer the hitherto highest precision…
This paper discusses the multi-wavelength scanning Raman lidar being built at Lidar Division, CEILAP (CITEDEF-CONICET) in the frame of the Argentinean Cherenkov Telescope Array (CTA) collaboration to measure the spectral characteristics of…
Ultra Fast Silicon Detectors (UFSD) are sensors optimized for timing measurements employing a thin multiplication layer to increase the output signal. A multipurpose read-out board hosting a low-cost, low-power fast amplifier was designed…
The Isochronous Mass Spectrometry (IMS) is a powerful tool for mass measurements of exotic nuclei with half-lives as short as several tens of micro-seconds in storage rings. In order to improve the mass resolving power while preserving the…