English
Related papers

Related papers: The Micro Wire Detector

200 papers

We describe the first tests with a new proportional gas detector. Its geometry consists in slits opened in a copper metallized kapton foil with 30 micron anode strips suspended in these openings. In this way the multiplication process is…

Instrumentation and Detectors · Physics 2007-05-23 J. Claude Labbe , F. Gomez , T. Nunez , A. Pazos , P. Vazquez

The gaseous proportional counter is a device that can be used to detect ionizing radiation. These devices can be as simple as a cylindrical cathode and a very thin anode wire centered along its axis. By applying a high voltage, a strong…

Multiwire and microstrip porous detectors have been developed and investigated for DC operation. The multiwire porous detector consists of anode wires, an Al cathode and a gap between them filled with porous CsI. The microstrip porous…

Instrumentation and Detectors · Physics 2007-05-23 M. P. Lorikyan

We have developed a new detector of photons and charged particles- a hole-type structure with electrodes made of a double layered resistive material: a thin low resistive layer coated with a layer having a much higher resistivity. One of…

Instrumentation and Detectors · Physics 2008-11-26 G. Charpak , P. Benaben , P. Breuil , A. Di Mauro , P. Martinengo , V. Peskov

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…

Instrumentation and Detectors · Physics 2021-10-06 Rajendra Nath Patra , R. N. Singaraju , S. Biswas , T. K. Nayak , Y. P. Viyogi

A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…

Instrumentation and Detectors · Physics 2009-11-26 B. M. Ovchinnikov , V. I. Razin , A. I. Reshetin , S. N. Filippov

We have developed microstrip gas counters manufactured on standard printed circuit board and having the following features: resistive cathode strips, thin (10 micron) metallic anode strips and electrodes protected against surface discharges…

Instrumentation and Detectors · Physics 2011-07-28 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

We describe here various detectors designs: GEM type, MICROMEGAStype, PPACtype as well as cascaded detectors made of a resistive mesh manufactured from a resistive Kapton foil, (20 microns thick, resistivity a few MOhm per square) by a…

Instrumentation and Detectors · Physics 2017-10-11 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200…

Instrumentation and Detectors · Physics 2016-08-16 D. Bernard , H. Delagrange , D. G. d'Enterria , M. Le Guay , G. Martínez , M. J. Mora , P. Pichot , D. Roy , Y. Schutz , A. Gandi , R. de Oliveira

Full size single-sided GaAs microstrip detectors with integrated coupling capacitors and bias resistors have been fabricated on 3'' substrate wafers. PECVD deposited SiO_2 and SiO_2/Si_3N_4 layers were used to provide coupling capacitaces…

Instrumentation and Detectors · Physics 2009-10-30 R. Irsigler , R. Geppert , R. Goeppert , M. Hornung , J. Ludwig , M. Rogalla , K. Runge , Th. Schmid , A. Soldner-Rembold , M. Webel , C. Weber

Plastic gas pipes are widely used in experimental setups for gaseous detectors, due to their flexibility and easiness of use. This report describes the characterization studies realized on the use of plastic gas pipes, particularly in…

Instrumentation and Detectors · Physics 2022-02-25 Roberto Guida , Beatrice Mandelli , Mara Corbetta , Tomoo Mari

We have developed a novel technique for the measurement of the avalanche fluctuation of gaseous detectors using a UV laser. The technique is simple and requires a short data-taking time of about ten minutes. Furthermore, it is applicable…

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

A detector with a profile-based cathode and a pad-strip cathode readout system is experimentally investigated. Cathode pads arranged along each anode wire are diagonally interconnected and form strips that cross the detector at an angle…

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 V. Peskov , P. Fonte , M. Danielsson , C. Iacobaeus , J. Ostling , M. Wallmark

In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…

Instrumentation and Detectors · Physics 2007-05-23 P. Fonte , R. Ferreira-Marques , Y. Ivaniouchenkov , V. Peskov , A. Policarpo

Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard
‹ Prev 1 2 3 10 Next ›