English
Related papers

Related papers: Gas electron multiplier: performance and possibili…

200 papers

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

We study the performance of the triple-GEM (Gas Electron Multiplier) detector in pure noble gases Ne, Ar and Xe, at different pressures varying from 1 to 10 atm. In Ar and Xe, the maximum attainable gain of the detector abruptly drops down…

Instrumentation and Detectors · Physics 2009-11-07 A. Bondar , A. Buzulutskov , L. Shekhtman

Gas Electron Multiplier (GEM) is a cutting edge Micro Pattern Gaseous detector (MPGD) technology suitable as tracking device in high rate Heavy-Ion (HI) experiments for their good spatial resolution and most importantly high rate handling…

High Energy Physics - Experiment · Physics 2025-05-07 S. Mandal , S. Gope , S. Das , S. Biswas

Gas detector are very light instrument used in high energy physics to measure the particle properties: position and momentum. Through high electric field is possible to use the Gas Electron Multiplier (GEM) technology to detect the charged…

The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…

Instrumentation and Detectors · Physics 2015-10-28 Kiadtisak Saenboonruang , Piyakul Kumphiranon , Kittipong Kulasri , Anawat Ritthirong

We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs…

Instrumentation and Detectors · Physics 2011-04-11 R. Chechik , A. Breskin , C. Shalem

In this paper, the performances of a type of the domestic THGEM (THick Gaseous Electron Multiplier) working in the Ar/CO2 mixtures are reported in details. This kind of single THGEM can provide the gain range from 100 to 1000, which is very…

In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a…

Instrumentation and Detectors · Physics 2022-07-13 Vishal Kumar , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkara

We present the results of our recent studies of a Thick Gaseous Electron Multiplier (THGEM)-based detector, operated in Ar, Xe and Ar:Xe (95:5) at various gas pressures. Avalanche-multiplication properties and energy resolution were…

Instrumentation and Detectors · Physics 2009-11-13 R. Alon , J. Miyamoto , M. Cortesi , A. Breskin , R. Chechik , I. Carne , J. M. Maia , J. M. F. dos Santos , M. Gai , D. McKinsey , V. Dangendorf

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10{\mu}m) were studied. The maximum gain can reach 5{\times}103 and 2{\times}105 for single and double…

The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…

Instrumentation and Detectors · Physics 2018-01-12 R. C. Roque , H. Natal da Luz , L. F. N. D. Carramate , C. D. R. Azevedo , J. A. Mir , F. D. Amaro

We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…

Instrumentation and Detectors · Physics 2009-11-11 A. Bondar , A. Buzulutskov , A. Grebenuk , D. Pavlyuchenko , R. Snopkov , Y. Tikhonov

The first operation of GEM gas gain elements in negative ion gas mixtures is reported. Gains up to several thousand were obtained from single-stage GEMs in carbon disulfide vapor at low pressure, and in mixtures of carbon disulfide with…

Instrumentation and Detectors · Physics 2009-11-10 J. Miyamoto , I. Shipsey , C. J. Martoff , M. Katz-Hyman , R. Ayad , G. Bonvicini , A. Schreiner

The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it…

Instrumentation and Detectors · Physics 2016-06-24 M. Cortesi , S. Rost , W. Mittig , Y. Ayyad Limonge , D. Bazin , J. Yurkon , A. Stolz

The dependence of the avalanche charge gain in Thick Gas Electron Multipliers (THGEM) on the purity of Ne, Ar and Xe filling gases was investigated. The gain, measured with alpha-particles in standard conditions (atmospheric pressure, room…

Instrumentation and Detectors · Physics 2014-11-20 J. Miyamoto , A. Breskin , V. Peskov

The operation of Thick Gaseous Electron Multipliers (THGEM) in Ne and Ne/CH4 mixtures, features high multiplication factors at relatively low operation potentials, in both single- and double-THGEM configurations. We present some systematic…

Instrumentation and Detectors · Physics 2009-09-11 M. Cortesi , V. Peskov , G. Bartesaghi , J. Miyamoto , S. Cohen , R. Chechik , J. M. Maia , J. M. F. dos Santos , G. Gambarini , V. Dangendorf , A. Breskin

The Negative Ion Drift (NID) gas SF$_6$ has favourable properties for track reconstruction in directional Dark Matter (DM) searches utilising low pressure gaseous Time Projection Chambers (TPCs). However, the electronegative nature of the…

Instrumentation and Detectors · Physics 2023-11-20 A. G. McLean , N. J. C. Spooner , T. Crane , C. Eldridge , A. C. Ezeribe , R. R. Marcelo Gregorio , A. Scarff

The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…

We study the performance of Gas Electron Multipliers (GEMs) in gaseous He, Ne and Ne+H2 at temperatures in the range of 2.6-293 K. In He, at temperatures between 62 and 293 K, the triple-GEM structures often operate at rather high gains,…

Instrumentation and Detectors · Physics 2009-11-11 A. Buzulutskov , J. Dodd , R. Galea , Y. Ju , M. Leltchouk , P. Rehak , V. Tcherniatine , W. J. Willis , A. Bondar , D. Pavlyuchenko , R. Snopkov , Y. Tikhonov

It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the…

Instrumentation and Detectors · Physics 2021-04-28 Erik Brücken , Jouni Heino , Timo Hildén , Matti Kalliokoski , Vladyslav Litichevskyi , Raimo Turpeinen , Dezső Varga