Related papers: Gas electron multiplier: performance and possibili…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
The characteristic studies of a Single Mask~(SM) triple Gas Electron Multiplier (GEM) detector are carried out using Ar/CO$_2$ gas mixture in 70/30 volume ratio in continuous flow mode. A Fe$^{55}$ X-ray source is used for this work. The…
The gas gain of single-wire chambers filled with isobutane, with cell cross-section 12x12 mm and wire diameters of 15, 25, 50 and 100 $\mu$m, has been measured at pressures ranging 12-92 Torr. Contrary to the experience at atmospheric…
In view of a possible application as a charge-particle track readout for an Active Target Time Projection Chamber (AT-TPC), the operating properties of THick Gaseous Electron Multipliers (THGEM) in pure low-pressure Helium were…
We present net gain measurements at room temperature in Al$_{0.07}$Ga$_{0.93}$N/GaN 10-period multi-quantum well emitting at 367 nm, using the variable stripe length method. Measurements were conducted at two different positions on the…
Discrepancies between the measured and simulated gain in Thick Micropatterned gaseous detectors (MPGD), namely THGEM, have been observed by several groups. In order to simulate the electron avalanches and the gain the community relies on…
Gas electron multipliers (GEM) detectors are gaseous detectors widely used for tracking and imaging applications due to their good position resolution, high efficiency at high irradiation rates, among other factors. In the present work,…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
Argon gas doped with 1% wavelength-shifter (CF$_4$) has been employed in an optical time projection chamber (OTPC) to image cosmic radiation. We present results obtained during the system commissioning, performed with two stacked…
We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas…
Gas Electron Multiplier (GEM) detector, one of the advanced members of the Micro Pattern Gas Detector (MPGD) group, is widely used in High Energy Physics (HEP) experiments. The high rate handling capability and spatial resolution make it a…
The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter…
We study the performances of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation based on gas electron multipliers (GEMs) and operated in an avalanche mode in pure noble gases. The gas amplification in He, Ar and Kr…
In order to ensure proper SASE lasing of a fourth Generation light source, one of the goal is to produce an electron beam of small emittance and to conserve it until its used in the machine undulator. One of the non recoverable emittance…
A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…
In recent years Gas Electron Multipliers have proven to be reliable amplification stages at high beam rates, and can be used also in Time Projection Chambers. Our group developed a 1 dm$^3$ active volume double-GEM TPC, with spatial…
We study the feedback of positive ions in triple and quadruple Gas Electron Multiplier (GEM) detectors. The effects of GEM hole diameter, detector gain, applied voltages, number of GEMs and other parameters on ion feedback are investigated…
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure…
At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…
We present discharge probability studies performed with a single Thick Gas Electron Multiplier (THGEM) irradiated with alpha particles in Ar-CO$_2$ and Ne-CO$_2$ mixtures. We observe a clear dependency of the discharge stability on the…