Related papers: Sub-electron read noise at MHz pixel rates
Single-shot qubit readout typically combines high readout contrast with long-lived readout signals, leading to large signal-to-noise ratios and high readout fidelities. In recent years, it has been demonstrated that both readout contrast…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
The Multiple Amplifier Sensing Charge-Coupled Device (MAS-CCD) has emerged as a promising technology for astronomical observation, quantum imaging, and low-energy particle detection due to its ability to reduce the readout noise without…
Current optical space telescopes rely upon silicon Charge Coupled Devices (CCDs) to detect and image the incoming photons. The performance of a CCD detector depends on its ability to transfer electrons through the silicon efficiently, so…
Fast measurements of quantum devices is important in areas such as quantum sensing, quantum computing and nanodevice quality analysis. Here, we develop a superconductor-semiconductor multi-module microwave assembly to demonstrate charge…
To evidence multimode spatial entanglement of spontaneous down-conversion, detector arrays allow a full field measurement, without any a priori selection of the paired photons. We show by comparing results of the recent literature that…
Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived…
DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full…
The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause…
Single-photon detectors (SPDs) play important roles in highly sensitive detection applications, such as fluorescence spectroscopy, remote sensing and ranging, deep space optical communications, elementary particle detection, and quantum…
Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will…
We design and demonstrate a resonant-type differential photodetector for low-noise quantum homodyne measurement at 500MHz optical sideband with 17MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer…
The cross-correlation sensitivity of two identical balanced photodiode heterodyne receivers is characterized. Both balanced photodiodes receive the same weak signal split up equally, a situation equivalent to an astronomical spatial…
The solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to…
Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…
The EMCCD is a type of CCD that delivers fast readout times and negligible readout noise, making it an ideal detector for high frame rate applications which improve resolution, like lucky imaging or shift-and-add. This improvement in…
The High Luminosity upgrade of the CERN Large Hadron Collider will be able to reach a peak instantaneous luminosity of 5E34/cm2 s. The innermost detectors of the CMS and ATLAS experiments will have to cope with unprecedented requirements on…
The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…
We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve…