English
Related papers

Related papers: Comprehensive Design Validation of serially powere…

200 papers

In view of the High Luminosity LHC, the current CMS tracking detector will have to be replaced during Long Shutdown 3 to cope with the higher radiation environment and to withstand an increased data rate. To prepare for the so-called CMS…

Instrumentation and Detectors · Physics 2025-05-13 Giorgia Bonomelli

The next upgrade of the Large Hadron Collider (LHC) is planned from 2026 when the collider will move to its High Luminosity phase (HL-LHC). The CMS detector needs to be substantially upgraded during this period to exploit the fourfold…

Instrumentation and Detectors · Physics 2023-02-01 Tamas Almos Vami , Morris Swartz

The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…

Instrumentation and Detectors · Physics 2023-09-04 The Tracker Group of the CMS Collaboration

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are…

Instrumentation and Detectors · Physics 2022-12-12 The Tracker Group of the CMS Collaboration

At the High Luminosity LHC (HL-LHC), the CMS experiment will need to operate at up to 200 interactions per 25 ns beam crossing time and with up to 4000 fb-1 of integrated luminosity. To achieve the physics goals the experiment needs to…

Instrumentation and Detectors · Physics 2022-12-21 A. La Rosa , I. Ahmed , J. Almeida , G. Blanchot , S. Cooperstein , I. Dominguez , A. Honma , M. Kovacs , A. Zografos

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

Instrumentation and Detectors · Physics 2011-10-11 N. Parashar

The High-Luminosity LHC (HL-LHC) era, set to begin in 2029, will provide the general-purpose experiments with an instantaneous luminosity of up to $\mathcal{L} = 7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ from pp collisions at a centre-of-mass…

High Energy Physics - Experiment · Physics 2025-01-08 Thiago R. F. P. Tomei

The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…

High Energy Physics - Experiment · Physics 2025-02-11 Clara Lasaosa

The High-Luminosity LHC (HL-LHC) will usher in a new era in high-energy physics. The HL-LHC experimental conditions entail an instantaneous luminosity of up to $7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ and up to 200 simultaneous collisions…

High Energy Physics - Experiment · Physics 2022-11-17 Thiago R. F. P. Tomei

The LHC machine is planning an upgrade program, which will smoothly bring the instantaneous luminosity to about $5-7.5\times10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ in 2028, to possibly reach an integrated luminosity of 3000-4500 fb$^{-1}$…

Instrumentation and Detectors · Physics 2019-11-07 Ernesto Migliore

A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly…

Instrumentation and Detectors · Physics 2016-12-23 Simon Spannagel

The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of $2 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}$. Both barrel and endcap disk systems now feature one…

Instrumentation and Detectors · Physics 2018-07-25 Jory Sonneveld

The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…

Instrumentation and Detectors · Physics 2015-05-15 Simon Spannagel

The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…

Instrumentation and Detectors · Physics 2023-01-26 Sascha Liechti

The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…

Instrumentation and Detectors · Physics 2023-03-08 The Tracker Group of the CMS Collaboration

The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced…

Instrumentation and Detectors · Physics 2010-01-25 H. C. Kästli

During the high-luminosity phase of the LHC (HL-LHC), planned to start around 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to $7.5\times10^{34}$ cm$^{-2}$s$^{-1}$. A total integrated luminosity of…

Instrumentation and Detectors · Physics 2020-06-17 The Tracker Group of the CMS Collaboration

During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates,…

Instrumentation and Detectors · Physics 2022-01-19 A. Samalan , M. Tytgat , G. A. Alves , F. Marujo , F. Torres Da Silva De Araujo , E. M. DaCosta , D. De Jesus Damiao , H. Nogima , A. Santoro , S. Fonseca De Souza , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , M. Bonchev , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , C. Bernal , A. Cabrera , J. Fraga , A. Sarkar , S. Elsayed , Y. Assran , M. El Sawy , M. A. Mahmoud , Y. Mohammed , C. Combaret , M. Gouzevitch , G. Grenier , I. Laktineh , L. Mirabito , K. Shchablo , I. Bagaturia , D. Lomidze , I. Lomidze , V. Bhatnagar , R. Gupta , P. Kumari , J. Singh , V. Amoozegar , B. Boghrati , M. Ebraimi , R. Ghasemi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , R. Aly , W. Elmetenawee , N. DeFilippis , A. Gelmi , G. Iaselli , S. Leszki , F. Loddo , I. Margjeka , G. Pugliese , D. Ramos , M. Caponero , L. Benussi , S. Bianco , S. Colafranceschi , A. Russo , L. Passamonti , D. Piccolo , D. Pierluigi , G. Saviano , S. Buontempo , A. Di Crescenzo , F. Fienga , G. DeLellis , L. Lista , S. Meola , P. Paolucci , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , B. Francois , T. J. Kim , J. Park , S. Y. Choi , B. Hong , K. S. Lee , J. Goh , H. Lee , J. Eysermans , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , C. A. Mondragon Herrera , D. A. Perez Navarro , G. A. AyalaSanchez , S. Carrillo , E. Vazquez , N. Zaganidis , A. Radi , A. Ahmad , I. Asghar , H. Hoorani , S. Muhammad , M. A. Shah , B. Mandelli , R. Guida , I. Crotty

Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions.…

Instrumentation and Detectors · Physics 2020-03-26 Viktoria Hinger

Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has…

Instrumentation and Detectors · Physics 2011-10-07 Gemma Tinti
‹ Prev 1 2 3 10 Next ›