The phase 1 upgrade of the CMS pixel detector has been designed to maintain the tracking performance at instantaneous luminosities of 2×1034 cm2 s12 \times 10^{34} \mathrm{~cm}^{-2} \mathrm{~s}^{-1}. Both barrel and endcap disk systems now feature one extra layer (4 barrel layers and 3 endcap disks), and a digital readout that provides a large enough bandwidth to read out its 124M pixel channels (87.7 percent more pixels compared to the previous system). The backend control and readout systems have been upgraded accordingly from VME-based to micro-TCA-based ones. The detector is now also equipped with a bi-phase CO2_2 cooling system that reduces the material budget in the tracking region. The detector has been installed inside CMS at the start of 2017 and is now taking data. These proceedings discuss experiences in the commissioning and operation of the CMS phase 1 pixel detector. The first results from the CMS phase 1 pixel detector with this year's LHC proton-proton collision data are presented. The new pixel detector outperforms the previous one in terms of hit resolution, tracking, and vertex resolution.

Keywords

Cite

@article{arxiv.1807.08987,
  title  = {Commissioning and first results from the CMS phase 1 upgrade pixel detector},
  author = {Jory Sonneveld},
  journal= {arXiv preprint arXiv:1807.08987},
  year   = {2018}
}

Comments

11 pages, 8 figures. Contribution to the proceedings of the 26th International Workshop on Vertex Detectors (Vertex2017) in Las Caldas, Asturias, Spain, 10-15 September, 2017