Related papers: Commissioning and first results from the CMS phase…
A new pixel detector for the CMS experiment is being built, owing to the instantaneous luminosities anticipated for the Phase I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking while featuring a significantly…
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical…
The Phase-1 upgrade of the CMS pixel detector is built out of four barrel layers (BPix) and three forward disks in each endcap (FPix). It comprises a total of 124M pixel channels in 1,856 modules, and it is designed to withstand…
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…
The CMS tracker consists of two tracking systems utilizing semiconductor technology: the inner pixel and the outer strip detectors. The tracker detectors occupy the volume around the beam interaction region between 3 cm and 110 cm in radius…
The LHC machine at CERN finished its first year of pp collisions at a center of mass energy of 7 TeV. While the commissioning to exploit its full potential is still ongoing, there are plans to upgrade its components to reach instantaneous…
The CMS inner pixel detector system is planned to be replaced during the first phase of the LHC luminosity upgrade. The plans foresee an ultra low mass system with four barrel layers and three disks on either end. With the expected increase…
The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…
The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced…
The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…
The CMS experiment will include a pixel detector for pattern recognition and vertexing. It will consist of three barrel layers and two endcaps on each side, providing three space-points up to a pseudoraditity of 2.1. Taking into account the…
The CMS Phase-1 pixel detector was extracted from the underground cavern after the end of the LHC Run-2 in 2019 and has been kept cold to protect the silicon sensors during the long shutdown period (LS2) in 2019-2021. The LHC is now…
After the Large Hadron Collider (LHC) upgrade into High Luminosity LHC (HL-LHC), the instantaneous luminosity is expected to reach values up to 7.5x10^34cm^2/s, causing a harsher radiation environment as well as a significant increase in…
The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…
The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The detector is made of three barrel layers and two disks at each end of the barrel. Detector…
The CMS Pixel detector, consisting of three barrel layers and two endcap disks at each barrel end, was installed in the CMS experiment in summer 2008. After a preliminary commissioning phase with pulse injections the detector participated…
The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a center-of-mass energy of 14 TeV and to reach the unprecedented peak instantaneous luminosity of $7.5 \times 10^{34} \text{cm}^{-2} \text{s}^{-1}$…
The CMS experiment at the LHC has started data taking in Run 3 at a $\mathrm{pp}$ collision energy of $13.6~\mathrm{TeV}$. In preparation for Run 3, detector systems, such as Pixel Tracker, HCAL and CSC, have been upgraded due to…
In the first LHC running period the CMS-pixel detector had to face various operational challenges and had to adapt to the rapidly changing beam conditions. In order to maximize the physics potential and the quality of the data, online and…
The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…