Related papers: 4D Vessel Reconstruction for Benchtop Thrombectomy…
In the framework of multidimensional Compressed Sensing (CS), we introduce an analytical reconstruction formula that allows one to recover an $N$th-order $(I_1\times I_2\times \cdots \times I_N)$ data tensor $\underline{\mathbf{X}}$ from a…
Femoral artery access is essential for numerous clinical procedures, including diagnostic angiography, therapeutic catheterization, and emergency interventions. Despite its critical role, successful vascular access remains challenging due…
Tissue deformation in ultrasound (US) imaging leads to geometrical errors when measuring tissues due to the pressure exerted by probes. Such deformation has an even larger effect on 3D US volumes as the correct compounding is limited by the…
Although the socket is critical in a prosthetic system for a person with limb amputation, the methods of its design are largely artisanal. A roadblock for a repeatable and quantitative socket design process is the lack of predictive and…
The outcome of vertebroplasty is hard to predict due to its dependence on complex factors like bone cement and marrow rheologies. Cement leakage could occur if the procedure is done incorrectly, potentially causing adverse complications. A…
When a blood vessel ruptures or gets inflamed, the human body responds by rapidly forming a clot to restrict the loss of blood. Platelets aggregation at the injury site of the blood vessel occurring via platelet-platelet adhesion, tethering…
Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynamics but require long acquisition times, precluding its widespread use for early diagnosis of cardiovascular disease. To reduce the acquisition times, reconstruction…
High energy impacts at joint locations often generate highly fragmented, or comminuted, bone fractures. Current approaches for treatment require physicians to decide how to classify the fracture within a hierarchy fracture severity…
We propose a novel low-rank tensor method for respiratory motion-resolved multi-echo image reconstruction. The key idea is to construct a 3-way image tensor (space $\times$ echo $\times$ motion state) from the conventional gridding…
4D-flow magnetic resonance imaging (MRI) is an emerging imaging technique where spatiotemporal 3D blood velocity can be captured with full volumetric coverage in a single non-invasive examination. This enables qualitative and quantitative…
Purpose: Anthropomorphic phantoms can be used in radiotherapy to confirm dose distributions. In this work, a prototype phantom with a deformable chest wall was created based on real human. Methods: A technique similar to 3-dimensional…
This work introduces a 4D-flow magnetic resonance imaging (MRI) pressure reconstruction method which employs weighted least-squares (WLS) for pressure integration. Pressure gradients are calculated from the velocity fields, and velocity…
Limited-angle computed tomography (LACT) reconstruction is an inverse problem with severe ill-posedness arising from missing projection angles, and it is difficult to restore high-precision images without sufficient prior knowledge. In…
Reconstructing dynamic, time-varying scenes with computed tomography (4D-CT) is a challenging and ill-posed problem common to industrial and medical settings. Existing 4D-CT reconstructions are designed for sparse sampling schemes that…
Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive…
During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides…
Recent 3D feed-forward models, such as the Visual Geometry Grounded Transformer (VGGT), have shown strong capability in inferring 3D attributes of static scenes. However, since they are typically trained on static datasets, these models…
Even for short protocols (<1 min), head movement can compromise accurate haemodynamic modelling of cerebral CT perfusion (CTP) imaging in acute stroke. Frame-to-frame registration is the most common form of retrospective correction but…
Two finite element approximations of the Oldroyd-B model for dilute polymeric fluids are considered, in bounded 2- and 3-dimensional domains, under no flow boundary conditions. The pressure and the symmetric conformation tensor are…
The treatment of intracranial aneurysms (IA) relies on angiography guidance using biplane views. However, accurate flow estimation and device sizing for treatment are often compromised by vessel overlap and foreshortening, which can obscure…