Related papers: Spatial resolution improvement of PICOSEC Micromeg…
In the last years, optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass anode coupled to a CMOS camera. Effective X-ray radiography was demonstrated using integrated imaging…
The water Cherenkov detector array (WCDA) is one of the key detectors in the large high altitude air shower observatory (LHAASO), which is proposed for very high gamma ray source survey. In WCDA, there are more than 3000 photomultiplier…
Time resolution is one of the most severe limitations of scanning probe microscopies (SPMs), since the typical image acquisition times are in the order of several seconds or even few minutes. As a consequence, the characterization of…
Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector…
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO)…
A large volume Time Projection Chamber (TPC) has been proposed as main tracking device at the International Linear Collider (ILC). Gas electron multipliers (GEMs) are studied as potential replacement of the conventional wire based gas…
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The…
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6…
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides…
In the readout electronics of the Water Cerenkov Detector Array (WCDA) in the Large High Altitude Air Shower Observatory (LHAASO), both high-resolution charge and time measurement are required over a dynamic range from 1 photoelectron…
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out with 1D strips or pad structures, here the characterisation…
Synchrotron radiation light sources produce intense beam of X-ray with ultra-short pulse and nanosecond period. This of-fers the opportunities for the time resolution experiments. Achieving higher counting rate and faster arriving time is…
We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber ({\mu}PIC) coupled with a field-programmable-gate-array-based data acquisition system. Our…
The development of CMOS pixel sensors with column parallel read-out and integrated zero-suppression has resulted in a full size, nearly 1 Megapixel, prototype with ~100 \mu s read-out time. Its performances are quite close to the ILD vertex…
The TORCH time-of-flight detector is designed to provide a 15 ps timing resolution for charged particles, resulting in $\pi$/$K$ particle identification up to 10 GeV/c momentum over a 10 m flight path. Cherenkov photons, produced in a…
The PAMELA apparatus has been assembled and it is ready to be launched in a satellite mission to study mainly the antiparticle component of cosmic rays. In this paper the performances obtained for the silicon microstrip detectors used in…
TORCH is a novel time-of-flight detector that has been developed to provide charged-particle identification between 2 and 10 GeV/c momentum. TORCH combines arrival times from multiple Cherenkov photons produced within a 10 mm-thick quartz…
We report the calibration of a gaseous Time Projection Chamber based on Micromegas charge readout modules with cosmic ray muons, utilizing their penetrating power and relatively uniform energy deposition per unit length. Muon events were…
This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…
The present study proposed the framework of the spatiotemporal superresolution measurement based on the sparse regression with dimensionality reduction using the proper orthogonal decomposition (POD). The non-time-resolved particle image…