In the last years, optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass anode coupled to a CMOS camera. Effective X-ray radiography was demonstrated using integrated imaging approach. High granularity values have been reached for low-energy X-rays from radioactive sources and X-ray generators. Detector characterization with X-ray radiography has led to two applications: neutron imaging for non-destructive examination of highly gamma-ray emitting objects and beta imaging for the single cell activity tagging in the field of oncology drug studies. First measurements investigating the achievable spatial resolution of the glass Micromegas detector at the SOLEIL synchrotron facility with a high-intensity and flat irradiation field will be shown in this article.
@article{arxiv.2303.17444,
title = {X-ray imaging with Micromegas detectors with optical readout},
author = {A. Cools and S. Aune and F. Beau and F. M. Brunbauer and T. Benoit and D. Desforge and E. Ferrer-Ribas and A. Kallitsopoulou and C. Malgorn and E. Oliveri and T. Papaevangelou and E. C. Pollacco and L. Ropelewski and A. Sari and F. J. Iguaz},
journal= {arXiv preprint arXiv:2303.17444},
year = {2023}
}
Comments
6 pages, 4 figures, 7th International Conference on Micro Pattern Gaseous Detectors, 11-16 December 20223, Weizmann Institute of Science, Rehovot, Israel