English

Resolution Studies of GEM/Timepix Detector with 5 GeV electrons

Instrumentation and Detectors 2009-02-16 v1

Abstract

This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of 55×\times55 μm2\mu m^2) and its readout properties were investigated with 5 GeV electrons. The spatial resolution of the cluster center reconstruction was determined as a function of drift distance using different cluster alhoritms and compared with Monte Carlo predictions.

Keywords

Cite

@article{arxiv.0709.2837,
  title  = {Resolution Studies of GEM/Timepix Detector with 5 GeV electrons},
  author = {A. Bamberger and K. Desch and U. Renz and M. Titov and N. Vlasov and P. Wienemann and S. Zimmermann and A. Zwerger},
  journal= {arXiv preprint arXiv:0709.2837},
  year   = {2009}
}

Comments

Contributed paper to the Linear Collider Workshop (LCWS), Hamburg, May 31-June 4, (2007)