English
Related papers

Related papers: MgB$_2$ Thermal Kinetic Inductance Detector

200 papers

Thermal Kinetic Inductance Detectors (TKIDs) combine the excellent noise performance of traditional bolometers with a radio frequency multiplexing architecture that enables the large detector counts needed for the next generation of…

We show measurements of thermal kinetic inductance detectors (TKID) intended for millimeter wave cosmology in the 200-300 GHz atmospheric window. The TKID is a type of bolometer which uses the kinetic inductance of a superconducting…

Instrumentation and Methods for Astrophysics · Physics 2018-08-01 Bryan A. Steinbach , James J. Bock , Hien T. Nguyen , Roger C. O'Brient , Anthony D. Turner

Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in…

Instrumentation and Methods for Astrophysics · Physics 2022-09-07 J. J. A. Baselmans , F. Facchin , A. Pascual Laguna , J. Bueno , D. J. Thoen , V. Murugesan , N. Llombart , P. de Visser

We demonstrate strong negative electrothermal feedback accelerating and linearizing the response of a thermal kinetic inductance detector (TKID). TKIDs are a proposed highly multiplexable replacement to transition-edge sensors and measure…

We report on the development of Thermal Kinetic Inductance Detectors (TKIDs) suitable to perform X-ray spectroscopy measurements. The aim is to implement MKIDs sensors working in thermal quasi-equilibrium mode to detect X-ray photons as…

Microwave Kinetic Inductance Detectors, or MKIDs, are a type of low temperature detector that exhibit intrinsic frequency domain multiplexing at microwave frequencies. We present the first theory and measurements on a MKID based on a…

Superconductivity · Physics 2010-07-07 B. A. Mazin , D. Sank , S. McHugh , E. A. Lucero , A. Merrill , J. Gao , D. Pappas , D. Moore , J. Zmuidzinas

Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct…

The development of sensitive cryogenic light detectors is of primary interest for bolometric experiments searching for rare events like dark matter interactions or neutrino-less double beta decay. Thanks to their good energy resolution and…

Instrumentation and Detectors · Physics 2015-09-15 L. Cardani , I. Colantoni , A. Cruciani , S. Di Domizio , M. Vignati , F. Bellini , N. Casali , M. G. Castellano , A. Coppolecchia , C. Cosmelli , C. Tomei

For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors…

Instrumentation and Methods for Astrophysics · Physics 2015-06-26 Gerhard Ulbricht , Benjamin A. Mazin , Paul Szypryt , Alex B. Walter , Clint Bockstiegel , Bruce Bumble

We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting…

Kinetic inductance detectors (KIDs) show promise as a competitive technology for astronomical observations over a wide range of wavelengths. We are interested in comparing the fundamental limitations to the sensitivity of KIDs with that of…

Instrumentation and Methods for Astrophysics · Physics 2015-06-18 A. E. Lowitz , E. M. Barrentine , S. R. Golwala , P. T. Timbie

Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and…

Instrumentation and Methods for Astrophysics · Physics 2022-07-04 Nicholas Zobrist , W. Hawkins Clay , Grégoire Coiffard , Miguel Daal , Noah Swimmer , Peter Day , Benjamin A. Mazin

An electrothermal model of Kinetic Inductance Detectors (KIDs) is described. The non-equilibrium state of the resonator's quasiparticle system is characterized by an effective temperature, which because of readout-power heating is higher…

Instrumentation and Methods for Astrophysics · Physics 2015-04-21 Christopher N Thomas , Stafford Withington , David J Goldie

We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single…

Instrumentation and Detectors · Physics 2016-10-14 P. Szypryt , B. A. Mazin , G. Ulbricht , B. Bumble , S. R. Meeker , C. Bockstiegel , A. B. Walter

We have measured and compared the response of hybrid NbTiN-Al Microwave Kinetic Inductance Detectors (MKIDs) to changes in bath temperature and illumination by sub-mm radiation. We show that these two stimulants have an equivalent effect on…

Instrumentation and Detectors · Physics 2014-11-18 R. M. J. Janssen , A. Endo , P. J. de Visser , T. M. Klapwijk , J. J. A. Baselmans

Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal…

Instrumentation and Detectors · Physics 2014-01-13 D. J. Goldie , S. Withington

The highly sensitive millimeter-wave telescope is an important tool for accurate measurement of Cosmic Microwave Background (CMB) radiation, and its core component is a detector array located in a cryogenic focal plane. The feasibility of…

Instrumentation and Methods for Astrophysics · Physics 2024-01-29 Ye Chai , Shibo Shu , Yongping Li , Jiamin Sun , Zhouhui Liu , Yu Xu , Daikang Yan , Zhengwei Li , Yang Liu , Yiwen Wang , Weijie Guo , Juexian Cao , Congzhan Liu

We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors (MKIDs) made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of…

Cryogenic phonon detectors are adopted in light dark matter searches and coherent elastic neutrino-nucleus scattering experiments as they can achieve low energy thresholds. The phonon mediated sensing of silicon particle absorbers has…

Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the…

‹ Prev 1 2 3 10 Next ›