The foreseen CaLIPSO Positron Emission Tomography (PET) scanner is expected to yield simultaneously a fine image resolution, about 1 mm$^3$, and a high contrast. In this paper we present results of simulations for the full CaLIPSO PET…

Objective: Image reconstruction in high resolution PET scanners with depth of interaction (DOI) capability is computationally challenging due to the high sampling in detector and image space. This study evaluates the use of a virtual…

Total-Body PET (TB-PET) scanners represent a significant advancement in medical diagnostics, exemplified by the uEXPLORER, the world's first TB-PET system with an axial span of 194 cm, which exhibits exceptional sensitivity and spatial…

Instrumentation and Detectors · Physics 2025-04-10 D. Choudhary , S. Nag

PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high…

Instrumentation and Detectors · Physics 2014-09-22 Qiang Wang , Aswin J. Mathews , Ke Li , Jie Wen , Sergey Komarov , Joseph A. O'Sullivan , Yuan-Chuan Tai

The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…

Medical Physics · Physics 2012-03-23 A. Miceli , J. Glister , A. Andreyev , D. Bryman , L. Kurchaninov , P. Lu , A. Muennich , F. Retiere , V. Sossi

Preclinical research and organ-dedicated applications require high-resolution positron emission tomography (PET) detectors to visualize small structures and understand biological processes at a finer level of detail. Current commercial…

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

Presice measurements of the photons conversion points in the scintillators are required to achieve a high spatial resolution of the PET system. I have developed a new method of reconstruction of the depth-of-interaction information for PET…

Instrumentation and Detectors · Physics 2018-05-18 Andrei Yu. Semenov

The aim of this study was to optimize the design of a monolithic LGSO scintillation crystal and micro parallel-hole collimator for the development of a small-animal single photon emission computed tomography (SPECT) system with compact…

Medical Physics · Physics 2015-03-13 Joong Hyun Kim , Mikiko Ito , Soo Mee Kim , Seong Jong Hong , Jae Sung Lee

The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO)…

Instrumentation and Detectors · Physics 2024-06-28 A. Galindo-Tellez , V. Sharyy , C. -H. Sung , M. Follin , L. Cappellugola , S. Curtoni , M. Dupont , C. Morel , D. Breton , J. Maalmi , D. Yvon

Depth-of-interaction (DOI) encoding is an effective strategy for reducing parallax error and preserving spatial resolution in positron emission tomography (PET), particularly in compact small-animal scanners. To enable efficient…

Medical Physics · Physics 2026-03-10 Satzhan Sitmukhambetov , Junwei Du , Mingwu Jin , Yujie Chi

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

Positron Emission Tomography (PET) using time-of-flight information, which can greatly improve the quality of the reconstructed image, has recently become an exciting topic. In this work, 3.2mm*3.2mm*25mm finger-like LYSO crystals were used…

Instrumentation and Detectors · Physics 2015-07-17 Liu Jun-Hui , Xu Jiong-Hui , Cheng Feng-Feng , Li Dao-Wu , Zhang Zhi-Ming , Wang Bao-Yi , Wei Long

Objective: Long-axial field-of-view (LAFOV) positron emission tomography (PET) systems allow higher sensitivity, with an increased number of detected lines of response induced by a larger angle of acceptance. However, this extended angle…

Differentiable rendering has been widely adopted in computer graphics as a powerful approach to inverse problems, enabling efficient gradient-based optimization by differentiating the image formation process with respect to millions of…

We developed a new and computationally simple local block-wise self attention based normal structures segmentation approach applied to head and neck computed tomography (CT) images. Our method uses the insight that normal organs exhibit…

Computer Vision and Pattern Recognition · Computer Science 2019-09-12 Jue Jiang , Elguindi Sharif , Hyemin Um , Sean Berry , Harini Veeraraghavan

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes…

Image and Video Processing · Electrical Eng. & Systems 2024-04-18 Shaoyan Pan , Elham Abouei , Junbo Peng , Joshua Qian , Jacob F Wynne , Tonghe Wang , Chih-Wei Chang , Justin Roper , Jonathon A Nye , Hui Mao , Xiaofeng Yang

Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of…

Positron Emission Tomography (PET) scanners are usually designed with the goal to obtain the best compromise between sensitivity, resolution, field-of-view size, and cost. Therefore, it is difficult to improve the resolution of a PET…

Medical Physics · Physics 2023-07-18 Pablo Galve , Alejandro Lopez-Montes , Jose M Udias , Stephen C Moore , Joaquin L Herraiz