Related papers: Novel Asymmetrical High-Resolution and High-Sensit…
Purpose: To apply a convolutional neural network (CNN) to develop a system that segments intensity calibration phantom regions in computed tomography (CT) images, and to test the system in a large cohort to evaluate its robustness. Methods:…
This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…
A systematic study is conducted to understand the coincident resolving time (CRT) for a pair of Lutetium-yttrium oxyorthosilicate (LYSO) and the plastic scintillation detector bars under the Geant4 framework. Crystals are coupled to a…
The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…
In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30 ps TOF resolution,…
Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$)…
Background: Diagnostic PET image quality depends on the administered activity and acquisition time. However, minimizing these variables is desirable to reduce patient radiation exposure and radiopharmaceutical costs. PETfectior is an…
This study demonstrates the feasibility of a novel fabrication technique for high spatial resolution CsI: Tl scintillation detectors tailored for single photon emission computed tomography (SPECT) systems. Building upon our previously…
In PET, the amount of relative (signal-dependent) noise present in different body regions can be significantly different and is inherently related to the number of counts present in that region. The number of counts in a region depends, in…
In this paper, we provide a precise mathematical model of crystal-to-crystal response which is used to generate the white image - a necessary compensation model needed to overcome the physical limitations of the PET scanner. We present a…
This study proposes a deep learning-based framework for automated segmentation of brain regions and classification of amyloid positivity using positron emission tomography (PET) images alone, without the need for structural MRI or CT. A 3D…
Head movement poses a significant challenge in brain positron emission tomography (PET) imaging, resulting in image artifacts and tracer uptake quantification inaccuracies. Effective head motion estimation and correction are crucial for…
Positron emission tomography (PET) suffers from severe resolution limitations which limit its quantitative accuracy. In this paper, we present a super-resolution (SR) imaging technique for PET based on convolutional neural networks (CNNs).…
In this report, we present a fast and accurate object detection method dubbed DAMO-YOLO, which achieves higher performance than the state-of-the-art YOLO series. DAMO-YOLO is extended from YOLO with some new technologies, including Neural…
We develop and evaluate MlPET, a fast localized machine learning approach for probabilistic PET image analysis addressing the noise-resolution trade-off in conventional reconstructions. MlPET replaces computationally demanding Markov chain…
Single Photon Emission Computed Tomography (SPECT) is a non-invasive imaging modality, frequently used in myocardial perfusion imaging. The biggest challenges facing the majority of clinical SPECT systems are low sensitivity, poor…
In positron emission tomography (PET), a clear theoretical model describing how system sensitivity varies as a source is moved trans-axially within the field of view (FOV) is lacking. The current understanding and practical intuition often…
Small animal PET scanners require high spatial resolution and good sensitivity. To reconstruct high-resolution images in 3D-PET, iterative methods, such as OSEM, are superior to analytical reconstruction algorithms, although their high…