English
Related papers

Related papers: A muon scattering tomography system based on high …

200 papers

Radiography with cosmic ray muon scattering has proven to be a successful method of imaging nuclear material through heavy shielding. Of particular interest is monitoring dry storage casks for diversion of plutonium contained in spent…

Instrumentation and Detectors · Physics 2018-03-14 D. Poulson , J. M. Durham , E. Guardincerri , C. L. Morris , J. D. Bacon , K. Plaud-Ramos , D. Morley , A. Hecht

In recent years, muon tomography has turned into a powerful and innovative technique for non-invasive imaging of large and small structures with applications in different areas like geology, archaeology, security, etc. We present the design…

High Energy Physics - Experiment · Physics 2025-12-12 J. A. Rengifo , J. L. Bazo

A CdTe double-sided strip detector (CdTe-DSD) is an ideal device for imaging and spectroscopic measure- ments in the hard X-ray range above 10 keV. Recent development enables us to realize an imager with a detection area of ~10 cm${^2}$. An…

Muons interact with matter via two major interaction mechanisms: ionization and radioactive process, and multiple Coulomb scattering leading to energy loss and trajectory deflection, respectively. For a monoenergetic muon beam crossing an…

Instrumentation and Detectors · Physics 2018-08-24 Zhengzhi Liu

Cosmic rays interacting with the atmosphere result in a flux of secondary particles including muons and electrons. Atmospheric ray tomography (ART) uses the muons and electrons for detecting objects and their composition. This paper…

Quality assurance and condition assessment of concrete structures is an important topic world-wide due to the ageing infrastructure and increasing traffic demands. Common topics include, but are not limited to, localisation of rebar or…

Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…

High Energy Physics - Experiment · Physics 2026-05-07 Yan Niu , Anqing Wang , Xiangxiang Ren , Dong Liu , Meng Wang

The research focuses on the non-invasive imaging technique using cosmic muon absorption tomography to monitor the internals of archaeological / civil / industrial structures of intermediate size. It integrates experimental measurements and…

Instrumentation and Detectors · Physics 2025-04-01 Piyush Pallav , Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar

X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we…

Instrumentation and Detectors · Physics 2015-01-29 Burkhant Suerfu , Christopher G. Tully

This report presents the design, characterization, and application of a high-sensitivity optical detection system based on plastic scintillators coupled to Multi-Pixel Photon Counters (MPPCs). The primary objective was to evaluate the…

Instrumentation and Detectors · Physics 2026-02-24 Sahla Manithottathil , Anuj Gupta , Mudit Kumar , Navaneeth Poonthottathil

Cosmic ray muons enable non-invasive imaging of dense structures through multipleCoulomb scattering (MCS), with scattering angles dependent on atomic number (Z). Traditional algorithms like Point of Closest Approach (PoCA) assume single…

Applied Physics · Physics 2026-03-09 Reshma Ughade , Stylianos Chatzidakis

A scintillation muon telescope module with fiber-optic light collection using silicon photomultipliers was developed, tested, and installed for continuous monitoring to study cosmic ray variations. The aim of this study was to create a…

Instrumentation and Methods for Astrophysics · Physics 2026-02-10 Belov S. M. , Yanke V. G

In cultural heritage conservation, it is increasingly common to rely on non-destructive imaging methods based on the absorption or scattering of photons ($X$ or $\gamma$ rays) or neutrons. However, physical and practical issues limit these…

Due to the muon tomography's capability of imaging high Z materials, some potential applications have been reported on inspecting smuggled nuclear materials in customs. A compact Cosmic Ray Muons (CRM) imaging prototype, Lanzhou University…

Highly energetic, cosmic-ray muons can easily penetrate a dry storage cask and yield information about the material inside it by making use of the physics of multiple Coulomb scattering. Work by others has shown this information may be used…

Instrumentation and Detectors · Physics 2018-02-01 Zhengzhi Liu , Jason Hayward , Can Liao , Haori Yang

Muon tomography is a non-destructive imaging technique that uses cosmic-ray muons to probe dense materials. Bar scintillator and scintillating fiber detectors equipped with one-dimensional SiPM arrays offer compact, high-resolution…

Instrumentation and Detectors · Physics 2026-04-06 Chenghan Lv , Kun Hu , Huiling Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Weiwei Xu

The past several decades have seen significant advancement in applications using cosmic-ray muons for tomography scanning of unknown objects. One of the most promising developments is the application of this technique in border security for…

Instrumentation and Detectors · Physics 2026-05-05 Z. Zaher , H. Lay , T. Dorigo , A. Giammanco , V. Gulik , C. Hrytsiuk , V. A. Kudryavtsev , M. Lagrange , T. Metspalu , G. C. Strong , C. Turkoglu , P. Vischia

Muography (or muon radiography) is an imaging technique that relies on the use of cosmogenic muons as a free and safe radiation source. It can be applied in various fields such as archaeology, civil engineering, geology, nuclear reactor…

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

In this study, we employ the Monte Carlo simulations by using the GEANT4 code to demonstrate the capability of muon tomography based on the dual-parameter analysis in the examination of the nuclear waste barrels. Our current hodoscope setup…

Instrumentation and Detectors · Physics 2022-12-06 Ahmet Ilker Topuz , Madis Kiisk , Andrea Giammanco