English

Design of an atmospheric muon tomographer for material identification based on CORSIKA+GEANT4 simulations

High Energy Physics - Experiment 2025-12-12 v1 Instrumentation and Detectors

Abstract

In recent years, muon tomography has turned into a powerful and innovative technique for non-invasive imaging of large and small structures with applications in different areas like geology, archaeology, security, etc. We present the design and simulation of a transportable and easy to construct detector based on plastic scintillator and Silicon photomultipliers current technology. From a flux of cosmic rays reaching the atmosphere we simulated atmospheric muons at ground using CORSIKA. The detector and the object to analyze are simulated with GEANT4, where the previously obtained muon flux is transported. We use two methods for muon tomography to differentiate objects made of different materials: absorption and scattering. The statistical differences for several object sizes and materials are quantified. Using a threshold of 3 σ\sigma in the first method, we conclude that materials made of lead can be differentiated from objects made of other materials. The observation time needed to differentiate an object made of lead from one of aluminum was 4.9 and 9.9 days using the first and second method, respectively. In general, the absorption method gives the best results.

Keywords

Cite

@article{arxiv.2403.14948,
  title  = {Design of an atmospheric muon tomographer for material identification based on CORSIKA+GEANT4 simulations},
  author = {J. A. Rengifo and J. L. Bazo},
  journal= {arXiv preprint arXiv:2403.14948},
  year   = {2025}
}

Comments

Muon tomography, CORSIKA, GEANT4, plastic scintillator, SiPM