English
Related papers

Related papers: Performance Evaluation of a Position-Sensitive SiP…

200 papers

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…

Instrumentation and Detectors · Physics 2013-02-11 E. Guliyev , F. Ahmadov , G. Ahmadov , A. Sadigov , Z. Sadigov , N. Anfimov , Z. Krumshtein , A. Olshevski , V. Shvetsov , V. Zhezher , R. Madatov

We have designed, constructed, and tested an InGaAs near-infrared camera to explore whether low-cost detectors can make small (<1 m) telescopes capable of precise (<1 mmag) infrared photometry of relatively bright targets. The camera is…

Instrumentation and Methods for Astrophysics · Physics 2015-06-16 Peter W. Sullivan , Bryce Croll , Robert A. Simcoe

High-frequency sine wave gating (SWG) InGaAs/InP single-photon detectors (SPDs) are widely used for synchronous near-infrared single-photon detection. For practical use, the size of SPD is one of the most concerning features for system…

Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…

Instrumentation and Detectors · Physics 2026-03-30 B. Li , Y. Ma , K. Ni

This work concerns the development of a 3D measuring system able to realize noncontact surface topography with millimetric depth-range and micrometric resolutions both in the spatial and depth axes. The optical concept is based on the well…

Instrumentation and Detectors · Physics 2018-08-24 C. Pernechele , S. Chinellato , F. Manzan , S. Carmignato , A. Voltan

We describe a novel GaAs/AlGaAs double-quantum-well device for the infrared photon detection, called Charge-Sensitive Infrared Phototransistor (CSIP). The principle of CSIP detector is the photo-excitation of an intersubband transition in a…

Instrumentation and Methods for Astrophysics · Physics 2015-05-14 Y. Doi , Z. Wang , T. Ueda , P. Nickels , S. Komiyama , M. Patrashin , I. Hosako , S. Matsuura , M. Shirahata , Y. Sawayama , M. Kawada

Raman microscopy is a valuable tool for detecting physical and chemical properties of a sample material. When probing nanomaterials or nanocomposites the spatial resolution of Raman microscopy is not always adequate as it is limited by the…

This paper describes a new method for optical readout of Time Projection Chambers (TPCs), based on the Linearly Graded Silicon Photomultiplier (LG-SiPM). This is a single photon-sensitive detector with excellent timing and 2D position…

Instrumentation and Detectors · Physics 2020-12-15 A. Gola , K. Majumdar , G. Casse , K. Mavrokoridis , S. Merzi , L. Parsons Franca

A key requirement for autonomous on-orbit proximity operations is the estimation of a target spacecraft's relative pose (position and orientation). It is desirable to employ monocular cameras for this problem due to their low cost, weight,…

Computer Vision and Pattern Recognition · Computer Science 2021-01-26 Kevin Black , Shrivu Shankar , Daniel Fonseka , Jacob Deutsch , Abhimanyu Dhir , Maruthi R. Akella

A compact, portable and large field-of-view gamma camera to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities, which allow one to use…

In recent years, scientific Complementary Metal Oxide Semiconductor (sCMOS) devices have been increasingly applied in X-ray detection, thanks to their attributes such as high frame rate, low dark current, high radiation tolerance and low…

Instrumentation and Detectors · Physics 2022-12-14 Yu Hsiao , Zhixing Ling , Chen Zhang , Wenxin Wang , Quan Zhou , Xinyang Wang , Shuang-Nan Zhang , Weimin Yuan

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will…

A method of determination of a gamma quantum absorption point in a plastic scintillator block using a matrix of wavelength-shifting (WLS) strips is proposed. Application of this method for improvement of position resolution in newly…

Intraoperative Gamma Probe (IPG) remains the current gold standard modality for sentinel lymph node identification and tumor removal in cancer patients. However, even alongside the optical dyes they do not meet with <5% false negative rates…

Medical Physics · Physics 2022-01-26 S. Sajedi , L. Blackberg , S. Majewski , H. Sabet

This paper presents PointSSIM, a novel low-dimensional image-to-image comparison metric that is resolution invariant. Drawing inspiration from the structural similarity index measure and mathematical morphology, PointSSIM enables robust…

Computer Vision and Pattern Recognition · Computer Science 2025-07-01 Oscar Ovanger , Ragnar Hauge , Jacob Skauvold , Michael J. Pyrcz , Jo Eidsvik

We have constructed and tested a 2d position sensitive parallel-plate gas ionization chamber with scanned charge transfer readout. The scan readout method described here is based on the development of a new position dependent charge…

Instrumentation and Detectors · Physics 2009-11-10 F. Gomez , A. Iglesias , R. Lobato , J. Mosquera , J. Pardo , J. Pena , A. Pazos , M. Pombar , A. Rodriguez

Near-tissue computing requires sensor-level processing of high-resolution images, essential for real-time biomedical diagnostics and surgical guidance. To address this need, we introduce a novel Capacitive Transimpedance Amplifier-based…

Image and Video Processing · Electrical Eng. & Systems 2025-03-24 Zihan Yin , Subhradip Chakraborty , Ankur Singh , Chengwei Zhou , Gourav Datta , Akhilesh Jaiswal

In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

Imaging of nuclear gamma-ray lines in the 1-10 MeV range is far from being established in both medical and physical applications. In proton therapy, 4.4 MeV gamma rays are emitted from the excited nucleus of either 12^C^* or 11^B^* and are…

Instrumentation and Methods for Astrophysics · Physics 2018-05-17 Ayako Koide , Jun Kataoka , Takamitsu Masuda , Saku Mochizuki , Takanori Taya , Koki Sueoka , Leo Tagawa , Kazuya Fujieda , Takuya Maruhashi , Takuya Kurihara , Taku Inaniwa