English
Related papers

Related papers: Performance evaluation of compact plastic scintill…

200 papers

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

This paper describes an undergraduate-level physics project that incorporates various aspects of machine- and electronics-shop technical development. The desktop muon detector is a self-contained apparatus that employs plastic scintillator…

Physics Education · Physics 2017-12-06 Spencer N. Axani , Janet M. Conrad , Conor Kirby

Residual flux and angular distribution of high-energy cosmic muons have been measured in two underground locations at the Canfranc Underground Laboratory (LSC) using a dedicated Muon Monitor. The instrument consists of three layers of fast…

A muon telescope equipped with four Resistive Plate Chambers of 2 m$^{2}$ per plane was tested with the muon scattering tomography technique. The telescope was operated during several hours with high atomic number materials located at its…

Instrumentation and Detectors · Physics 2022-11-22 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test…

This paper reports on the design and construction of a chamber for the muon identifier detector (MID) of the ALICE 3 upgrade project. The chamber consists of two sensitive layers separated by a 1 cm air gap. Each layer holds 24 scintillator…

This work presents a novel cosmic-ray scattering experiment employing a Resistive Plate Chambers (RPC) muon tomography system. By introducing the scattering angle between incident and outgoing cosmic-ray tracks as a key observable, this…

Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon…

Instrumentation and Detectors · Physics 2016-04-15 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

Cosmic Ray Muon Radiography utilizes highly-penetrating cosmic ray muons to image the density profile of an object of interest. Here we report on the first trial to use a portable field-deployable cosmic ray tracking system in order to…

Cosmic ray muons have been considered as a non-conventional radiation probe in various applications. To utilize cosmic ray muons in engineering applications, two important quantities, trajectory and momentum, must be known. The muon…

Instrumentation and Detectors · Physics 2022-01-04 Junghyun Bae , Stylianos Chatzidakis

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…

Instrumentation and Detectors · Physics 2016-08-03 Shu-wen Tang , Yu-hong Yu , Yong Zhou , Zhi-yu Sun , Xue-heng Zhang , Shi-tao Wang , Ke Yue , Long-xiang Liu , Fang Fang , Duo Yan , Yu Sun , Zhao-min Wang

Cosmic-ray muon tomography is a promising technique for border security applications, leveraging highly penetrating cosmic-ray muons and their interactions with various materials to generate 3D images of large and dense objects, such as…

Applied Physics · Physics 2025-09-25 Anzori Sh. Georgadze

A CdTe double-sided strip detector (CdTe-DSD) is an ideal device for imaging and spectroscopic measure- ments in the hard X-ray range above 10 keV. Recent development enables us to realize an imager with a detection area of ~10 cm${^2}$. An…

We present a detailed study of an 8-channel $1\times1$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline.…

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

Cosmic ray muons enable non-invasive imaging of dense structures through multipleCoulomb scattering (MCS), with scattering angles dependent on atomic number (Z). Traditional algorithms like Point of Closest Approach (PoCA) assume single…

Applied Physics · Physics 2026-03-09 Reshma Ughade , Stylianos Chatzidakis

A high spatial resolution tracking system was setup with the Micro-mesh gaseous structure (Micromegas) detectors in order to study the muon tomographic imaging technique for nuclear threat detection. 6 layers of 90 mm $\times$ 90 mm…

Instrumentation and Detectors · Physics 2022-09-12 Liu Cheng-Ming , Wen Qun-Gang , Zhang Zhi-Yong , Huang Guang-Shun

The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of…

The cosmic ray veto (CRV) detector of the Mu2e experiment consists of four layers of plastic scintillation counters that surround the detector solenoid. These counters are embedded with wavelength-shifting fibers and are read out by silicon…

‹ Prev 1 4 5 6 7 8 10 Next ›