English

Time and Position Resolution of the Scintillator Strips for a Muon System at Future Colliders

Instrumentation and Detectors 2016-04-15 v3 High Energy Physics - Experiment

Abstract

Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per SiPM has been observed, as well as time resolution of 0.45 ns and position resolution along the strip of 7.7 cm.

Keywords

Cite

@article{arxiv.1512.06729,
  title  = {Time and Position Resolution of the Scintillator Strips for a Muon System at Future Colliders},
  author = {Dmitri Denisov and Valery Evdokimov and Strahinja Lukić},
  journal= {arXiv preprint arXiv:1512.06729},
  year   = {2016}
}

Comments

7 pages, 9 figures, accepted for publication in NIM A. arXiv admin note: substantial text overlap with arXiv:1510.03030