English
Related papers

Related papers: Embedding the Timepix4 in Micro-Pattern Gaseous De…

200 papers

The RD51 collaboration was founded in April 2008 to coordinate and facilitate efforts for development of micropattern gaseous detectors (MPGDs). The 59 institutes from 20 countries bundle their effort, experience and resources to develop…

Instrumentation and Detectors · Physics 2009-07-16 Serge Duarte Pinto

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles…

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides…

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…

Instrumentation and Detectors · Physics 2026-05-29 Sachin Rana , Md. Kaosor Ali Mondal , Poojan Angiras , Amal Sarkar

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…

The data compression technology now is fully developed and widely used in many fields such as communication, multi-media, image information processing and so on. The large physical experiments, especially the ones with Micro-pattern Gas…

Instrumentation and Detectors · Physics 2019-09-04 Zhongtao Shen , Shuwen Wang , Cheng Li , Changqing Feng , Shubin Liu

In-vacuum active pixel detectors enable high sensitivity, highly parallel time- and space-resolved detection of ions from complex surfaces. For the first time, a Timepix detector assembly was combined with a Secondary Ion Mass Spectrometer…

Instrumentation and Detectors · Physics 2013-09-05 András Kiss , Julia H. Jungmann , Donald F. Smith , Ron M. A. Heeren

In this work we have developed a prototype gaseous pixel detector by combining a micromegas grid with a Timepix3 chip for the readout. The micromegas foil supported by a matrix of pillars about 50 $\mathrm{\mu m}$ high was manually placed…

Instrumentation and Detectors · Physics 2019-04-10 S. Tsigaridas , M. v. Beuzekom , H. v. d. Graaf , F. Hartjes , K. Heijhoff , N. P. Hessey , P. J. de Jong , V. Prodanovic

We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron…

Instrumentation and Detectors · Physics 2008-11-26 A. Bamberger , K. Desch , U. Renz , M. Titov , N. Vlasov , P. Wienemann , A. Zwerger

A novel read-out architecture has been developed for the Micromegas detector. The anode element is made of a resistive layer on a ceramic substrate. The detector part is entirely separated from the read-out element. Without significant…

Instrumentation and Detectors · Physics 2015-06-11 D. Attie , A. Chaus , P. Colas , E. Ferrer , J. Galan , I. Giomatari , F. J. Iguaz , A. Gongadze , R. De Oliveira , T. Papaevangelou , A. Peyaud

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count,…

The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify…

Instrumentation and Detectors · Physics 2018-01-23 Ulrich Einhaus , Jochen Kaminksi , Michele Caselle

This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with…

We present a readout chip prototype for future pixel detectors with timing capabilities. The prototype is intended for characterizing 4D pixel arrays with a pixel size of $100\times100~\mu \text{m}^2$, where the sensors are Low Gain…

Instrumentation and Detectors · Physics 2023-02-15 Matias Senger , Lea Caminada , Benjamin Kilminster , Anna Macchiolo , Beat Meier , Stephan Wiederkehr

DataPix4 (Data Acquisition for Timepix4 Applications) is a new C++ framework for the management of Timepix4 ASIC, a multi-purpose hybrid pixel detector designed at CERN. Timepix4 consists of a matrix of 448x512 pixels that can be connected…

Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by…

The concept of a hybrid readout of a time projection chamber is presented. It combines a GEM-based amplification and a pad-based anode plane with a pixel chip as readout electronics. This way, a high granularity enabling to identify…

Instrumentation and Detectors · Physics 2017-04-06 Ulrich Einhaus , Jochen Kaminski

The Time Projection method is an ideal candidate to track low energy release particles. Large volumes can be readout by means of a moderate number of channels providing a complete 3D reconstruction of the charged tracks within the sensitive…

Instrumentation and Detectors · Physics 2019-01-15 G. Mazzitelli , E. Baracchini , G. Cavoto , E. Di Marco , M. Marafini , C. Mancini , D. Pinci , F. Renga , S. Tomassini