Related papers: Measured gain suppression in FBK LGADs with differ…
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche…
Low gain avalanche detectors can measure charged particle fluences with high speed and spatial precision, and are a promising technology for radiation monitoring and dosimetry. A detector has been tested in a medical linac where single…
Future high-energy physics experiments require a paradigm shift in radiation detector design. In response to this challenge, resistive LGADs that combine Low Gain Avalanche Diode technology with resistive readout have been developed. The…
With the High-Luminosity Large Hadron Collider (HL-LHC) the number of collisions per bunch crossing increases. To cope with these high rates in the pixel trackers, per-pixel time measurements are required, which implies the need for fast…
A novel methodology, named the diffusion profile method, is proposed in this research to measure the electric field of a low gain avalanche detector (LGAD).The proposed methodology utilizes the maximum of the time derivative of the edge…
The Gas Amplifier Detector with Germanium Tagging (GADGET) is a new detection system devoted to the measurement of weak, low-energy $\beta$-delayed proton decays relevant for nuclear astrophysics studies. It is comprised of a new gaseous…
Avalanche photodiode (APD) has been intensively investigated as a promising candidate to replace photomultiplier tubes (PMT) for weak light detection. However, in conventional APDs, a large portion of carrier energy drawn from the electric…
Avalanche photodiodes (APDs) are promising light sensor for various fields of experimental physics. It has been argued, however, that variation of APD gain with temperature could be a serious problem preventing APDs from replacing…
This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a ${}^{90}$Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61~ps was achieved,…
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy…
A Large Area Avalanche Photodiode (LAAPD) was studied, aiming to access its performance as light detector at low temperatures, down to -80 C. The excess noise factor, F, was measured and found to be approximately independent of the…
The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with…
Resistive Silicon Detectors (RSD, also known as AC-LGAD) are innovative silicon sensors, based on the LGAD technology, characterized by a continuous gain layer that spreads across the whole sensor active area. RSDs are very promising…
The increasing concentration of greenhouse gases, notably CH4 and CO2, has fueled global temperature increases, intensifying concerns regarding the prevailing climate crisis. Effectively monitoring these gases demands a detector spanning…
The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event…
We have developed Lumped Element Kinetic Inductance Detectors (LEKID) sensitive in the frequency band from 80 to 120~GHz. In this work, we take advantage of the so-called proximity effect to reduce the superconducting gap of Aluminium,…
Low-Gain Avalanche Diode (LGAD) sensors, offering timing resolutions of the order of tens of picoseconds, are being widely adopted in particle physics experiments and related applications. As these applications scale to large numbers of…
The measurement of light characteristics at the single- and few photon level plays a key role in many quantum optics applications. Often photodetection is preceded with the transmission of quantum light over long distances in optical fibers…
The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light, ~0.4% X_0, as required by the low energy of the…
We report on the development of a low-energy positron diffraction (LEPD) experimental station for surface structure analysis using a linac-based slow-positron beam. LEPD, the positron counterpart of low-energy electron diffraction (LEED),…