Related papers: IBIC analysis of a linear position sensitive detec…
For high-bias operation devices such as silicon carbide (SiC) power devices, early detection of failure mechanisms is essential to ensure reliability. This requires a method to map high electric fields with high spatial resolution, which…
The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW…
Focused electron beam induced deposition (FEBID) is a powerful technique for 3D-printing of complex nanodevices. However, for resolutions below 10 nm, it struggles to control size, morphology and composition of the structures, due to a lack…
We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states…
Using multi-channel time-resolved current measurements (multi TCT), the charge collection of p+n silicon strip sensors for electron-hole pairs produced close to the Si-SiO2 interface by a focussed sub-nanosecond laser with a wavelength of…
Focused ion beams (FIBs) are widely used in nanofabrication for applications such as circuit repair, ultra-thin lamella preparation, strain engineering, and quantum device prototyping. Although the lateral spread of the ion beam is often…
Lambda polarization can be measured through its self-analyzing weak decay, making it an ideal candidate for studying spin effects in high energy scatterings. In lepton-nucleon deeply inelastic scatterings (DIS), Lambda polarization…
Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce…
The Electron-Ion Collider (EIC) is an upcoming accelerator facility aimed at exploring the properties of quarks and gluons in nucleons and nuclei, shedding light on their structure and dynamics. The inaugural experimental apparatus, ePIC…
A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…
We report on the development of a low-energy positron diffraction (LEPD) experimental station for surface structure analysis using a linac-based slow-positron beam. LEPD, the positron counterpart of low-energy electron diffraction (LEED),…
Silicon carbide (SiC) is a promising material for radiation monitoring in harsh environments, due to its low dark current, high breakdown voltage, high thermal conductivity, and radiation hardness.~This work investigates a SiC-based…
This paper presents a new technique of optical beam-induced scattering of mid-IR-laser radiation, which is a special mode of the recently developed scanning mid-IR-laser microscopy. The technique in its present form is designed for…
A CMOS pixel sensor, named Supix-1, is developed for a pixelated silicon tracker for the Circular Electron-Positron Collider (CEPC) project. The sensor, consisted of nine sectors varying in pixel sizes, diode sizes and geometries, is…
When redox active molecules are covalently tethered to the surface of the n-doped silicon, light induces their oxidation by the semiconductor. To visualize this charge separation we have followed the formation and decay of the surface…
Silicon Detector (SiD) is one of the proposed detector for future $e^+e^-$ Linear colliders, like International Linear Collider (ILC). The estimated neutron background for ILC is around 1 - 1.6 x 1010 1-MeV equivalent neutrons cm-2 year-1…
Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Pre-clinical studies into their radiobiological effectiveness have established the prospect of using…
To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…
One of the possible ways to maintain the micrometer spatial resolution while performing ion beam analysis in the air is to increase the energy of ions. In order to explore capabilities and limitations of this approach, we have tested a…